Manual Switches

 

 

 

NT Series

Flat Base Sealed Toggles

 

 

 

 

NT 2-POSITION ORDER GUIDE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Circuits Made At:

 

 

Catalog

 

 

 

 

 

 

 

No. of

Keyway

Opposite

UL Rating

Electrical

Listing

 

Poles

Position

Keyway

Code

Rating Code

Toggle Q-C

 

 

 

 

 

 

 

 

 

OFF

2-3

L191

1

31NT91-2

1

1-2

2-3

L191

1

31NT91-3

 

OFF**

2-3

L192

2

31NT91-4

 

1-2**

OFF

L192

2

31NT91-6

 

1-2**

2-3

L192

2

31NT91-8

 

 

 

 

 

 

 

 

OFF

2-3, 5-6

L191

3

32NT91-2

2

1-2, 4-5

2-3, 5-6

L191

3

32NT91-3

 

OFF**

2-3, 4-6

L192

4

32NT91-4

 

1-2, 4-5**

OFF

L192

4

32NT91-6

 

1-2, 4-5**

2-3, 4-6

L192

4

32NT91-8

 

 

 

 

 

 

 

NT 3-POSITION ORDER GUIDE

 

 

 

 

 

 

 

 

Circuits Made At:

 

 

Electrical

Catalog

 

 

 

 

 

No. of

Keyway

Center

Opposite

UL Rating

Rating

Listing

Poles

Position

Position

Keyway

Code

Code

Toggle Q-C

 

 

 

 

 

 

 

 

1-2

OFF

2-3

L191

1

31NT91-1

1

1-2**

OFF

2-3

L192

2

31NT91-5

 

1-2**

OFF

2-3**

L192

2

31NT91-7

 

NONE***

OFF

2-3

L191

1

31NT91-21

 

NONE***

1-2

2-3

L191

1

31NT91-31

 

NONE***

1-2

2-3**

L192

2

31NT91-51

 

1-2**

OFF

NONE***

L192

2

31NT91-61

 

 

 

 

 

 

 

 

1-2, 4-5

OFF

2-3, 5-6

L191

3

32NT91-1

2

1-2, 4-5**

OFF

2-3, 5-6

L192

4

32NT91-5

 

1-2, 4-5**

OFF

2-3, 5-6**

L192

4

32NT91-7

 

NONE***

OFF

2-3, 5-6

L191

3

32NT91-21

 

NONE***

1-2, 4-5

2-3, 5-6

L191

3

32NT91-31

 

NONE***

1-2, 4-5

2-3, 5-6**

L192

4

32NT91-51

 

1-2, 4-5**

OFF

NONE***

L192

4

32NT91-61

 

1-2, 4-5

2-3, 4-5

2-3, 5-6

L191

3

32NT91-12

 

1-2, 4-5

1-2, 5-6

2-3, 5-6

L191

3

32NT91-10

 

1-2, 4-5**

1-2, 5-6

2-3, 5-6

L192

4

32NT91-50

 

1-2, 4-5**

1-2, 5-6

2-3, 5-6**

L192

4

32NT91-70

 

 

 

 

 

 

 

**These positions are momentary. All others are maintained.

***Toggle lever is blocked from these positions. Toggle becomes 2-position, with center being one extreme position.

MATING CONNECTORS ORDER GUIDE

 

 

Description

Catalog Listing

 

 

2-pole connector

19PA168-NT

 

 

1-pole connector, same package size as 2-pole connector

19PA169-NT

 

 

LOCKING CONFIGURATIONS

 

A

Locked In

Three Positions

B

Locked In

Center and

Extreme Position

(Keyway Side)

D

Locked Out

Of Center

Position

E

Locked In

Center Position

F

G

H

 

 

Locked Out Of

Locked In

Locked In

Center And

Extreme Position

Extreme Position

Extreme Position

(Opposite Keyway)

(Keyway Side)

(Keyway Side)

 

 

 

Toggle/Rockers

J

Locked Out Of

Center And

Extreme Position

(Opposite Keyway)

K

Locked In

Center And

Extreme Position

(Opposite Keyway)

L

Locked Out Of

Extreme Position

(Keyway Side)

M

Locked Out Of

And Into

Extreme Position

(Opposite Keyway)

N

Locked Out Of

Extreme Position

(Opposite Keyway)

P

Locked Out Of

And Into

Extreme Position

(Keyway Side)

Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada

127

Page 5
Image 5
Honeywell NR Series manual NT 2-POSITION Order Guide, NT 3-POSITION Order Guide, Mating Connectors Order Guide