TABLE 1: WIRE GAGE SPECIFICATIONS
Distance | Gage | 5 Conductor | 6 Conductor |
≤ 200 ft. (61m) | 22 | Alpha 1295C | Alpha 1296C |
≤300 ft. (91m) | 20 | Alpha 58126 | Alpha 58126 |
≤ 500 ft. (153 m) | 18 | Alpha 58136 | Alpha 58136 |
|
|
|
|
Note: Recommended cable is only a guideline, use any manufacturer that meets the gage and shield specifications.
HOW TO TEST AND OPERATE THE READER
The reader should be tested after wiring it to a power supply and the host. Do this by performing the following steps:
1.Power up the reader. The LED and beeper will activate three times. This indicates that the reader is working properly.
2.Present the appropriate type of ID card to the reader. (See Table 2 for the correct card type based on the reader model.) The LED will momentarily flash green and a short beep will be emitted. This indicates that the card was read properly by OmniProx.
3.After the card data is processed by the host, the host can then turn the LED green or yellow. Refer to the host description of the LED operation if the reader LED is controlled by the host.
Table 2: Model Number vs. Feature Matrix
Model | UL Listing | Card | Output | Read |
Number | Part # | Type | Format | Range |
|
|
|
| (Max.)* |
HID | Wiegand | 3” | ||
|
|
|
|
|
HID | Wiegand | 4” | ||
HID | Wiegand | 5” | ||
|
|
|
|
|
HID | Wiegand | 4” | ||
|
|
|
|
|
HID | Wiegand | 4” | ||
|
|
|
|
|
HID | Wiegand | 1.5” | ||
|
|
|
|
|
*Measured using HID Corp. Prox Card II (P/N 1326LSSMV) or equivalent and the corresponding OmniProx reader powered at 12 volts. Range also depends on electrical environment and/or proximity to metal.
SPECIFICATIONS
Electrical Characteristics:
Power Supply Type:
Linear type Recommended
Operating Voltage Range:
5.0– 16 VDC (Operational down to 4.25 VDC)
Maximum input current: OP10, OP20, OP90
Standby: 35 mA
Read: 50 mA OP30, OP40, OP45
Standby: 35 mA
Read: 100 mA
Tamper Output
Open collector, active low, max.sink current is 16 mA
Maximum Cable Distance to Host: 500 ft. (150 meters)
Card Read Distance:
See Table 2
Regulatory Approvals:
USA: UL 294 Listed & FCC Part 15 B (Model OP90 is not yet UL listed)
Europe: CE Listed
Operating Temperature Range:
Operating Humidity:
0 to 95% (non condensing) Suitable for outdoor use
Dimensions:
OP10:
3.15” (80mm) L x 1.58” (40mm) W x 0.50” (12.8mm) D
OP20:
4.73” (120mm) L x 1.65” (42mm) W x 0.55” (14mm) D
OP30:
5.71” (145mm) L x 1.69” (43mm) W x 0.79” (20mm) D
OP40:
4.33” (110mm) L x 2.96” (75mm) W x 0.59” (15mm) D
OP45:
3.5” (89mm) L x 3.5” (89mm) W x 0.59” (15mm) D
OP90:
4.72” (120mm) L x 3” (76mm) W x 1” (27mm) D
For additional information on the Wiegand™ Protocol, see “Access Control Standard – Wiegand Card Reader Interface SIA
OmniProx models with HID compatibility are capable of reading genuine HID cards under the terms of a license agreement between HID Corp. and the ADEMCO Group.