68-0173—3 8
Table 3. Heat Pump Applications (W8900B).
aAUX controls the auxiliary heat like W2, and allows additional stages of auxiliary heat with outdoor thermostats while maintain-
ing the proper second stage anticipation.
bFor systems without 2nd stage heat, configure W2 to No.
cFor systems requiring separate W1 and Y1 terminals for proper heat pump operation, refer to Fig. 18 and 19.
dReplace existing sensor with C7089A Outdoor Sensor.
W8900B Terminal
Designations Function
Existing Thermostat
Designations
(Standard)
Existing Thermostat
Designations
(Customer Specials)
1 PC8900A Control Panel — —
2 PC8900A Control Panel — —
3 PC8900A Control Panel — —
4 PC8900A Control Panel — —
AUXaStage-3 heat control (strip heat) W3 —
B Heating, changeover valve B —
C 24 Vac transformer common C X,B
CO2Carbon dioxide monitor — —
E Emergency heat relay E K
VNT VNT relay — —
G Fan relay G F
GND Ground — —
L System monitor L L
O Cooling, changeover valve O R
R 24 Vac system transformer R V
S, S1 Remote Air Temperature Sensor — —
T, T1 Discharge Air Temperature Sensor — —
W2bStage-2 heat control (compressor) W2 H2,Y,R4
Y1/W1cCompressor contactor — RS
Y1/W1cCompressor contactor Y M
Y1/W1cStage-1 cool control Y1 C1,M
Y1/W1cStage-1 heat control W1 H1,R3
Y2 Stage-2 cool control Y2 C2
None Clogged filter switch or common connection X X1,X2,C
None Defrost — P
None HSII Control Panel — L,C,H
None LEDs — A,A1,A2,Z,C,L
None LO and HI speed fan relays — R1,R2
None Momentary circuit, changeover — O
None Outdoor thermistor T A
OutdExternal temperature readout, T relay — —