69-1716 16
Step 7. Connect Wires to New Wallplate (Cont)
4. Loosen the screw terminals. Insert the labeled wires into the holes on the right side of the terminal block that match the letter designations. Tighten the screw terminals.5. If any of the labeled wires do not match the letter designations, see next page for wire connections.
G
O/B W
Y
R
M22176
RC
G
W/O/B
Y
R
RC
WALLPLATE
SCREW TERMINALS
TERMINAL BLOCK
INSERT WIRE IN HOLE
LABELED WIRES
WIRE HOLE
LETTER
DESIGNATIONS
NOT
USED
RC
R
Y
W
G