4.1Mounting ST 3000 Transmitter, Continued
Bracket mounting, | Table 8 | Mounting ST 3000 Transmitter to a Bracket, continued |
continued |
|
|
| Step | Action |
3Align appropriate mounting holes in transmitter with holes in bracket and secure with bolts and washers provided.
If transmitter is … | Then … |
DP type with | use alternate mounting |
process heads and/or | holes in end of heads. |
remote seals |
|
GP and AP with single- | use mounting holes in side |
ended head | of meter body. |
use smaller “U” bolt | |
(LGP model) | provided to attach meter |
| body to bracket. |
| See figure below. |
Dual head GP and AP | use mounting holes in end |
| of process head. |
Example – LGP model transmitter mounted to optional angle mounting bracket.
LGP Models
Meter Body
Smaller
“U” bolt
Use bracket for hexagonal meter body
NOTE: If the meter body is hexagonal, you must use the additional bracket supplied. If meter body is round, discard the bracket.
Continued on next page
2/05 | ST 3000 Release 300 Installation Guide | 25 |