T8001F, T8024F FLUSH MOUNT PROGRAMMABLE THERMOSTAT
5 69-1465—3
3. Setting Number of Cool/Heat Stages (T8024F
Only).
a. Press ▲ to display number of cool stages.
b. Press ▼ to change number of cool stages.
c. Press ▲ to display number of heat stages.
d. Press ▼ to change number of heat stages.
4. Setting Heat Cycle Rate (see Table 2) for the cycle
rate options and equipment.
a. Press the ▲ key to display the current heat
cycle rate setting of 1,3, 4, 5, 6, 9, or 12 cph.
NOTE: If thermostat is set to operate two stages of heat
(T8024 only), both stages operate at the
selected cycle rate.
b. To change the heat cycle rate, press the ▼ key
until your choice of 1, 3, 4, 5, 6, 9, or 12 is dis-
played. See Table 2.
c. Press the ▲ key to display control algorithm
configuration default.
d. Press the ▲ key again to change control algo-
rithm to C1 or C3.
C1 = Standard control algorithm.
C3 = Aggressive control algorithm (can
cause overshooting).
e. Press the ▲ key again. Current configuration
(CC) is displayed. A typical example is shown,
but CC varies by model. (This information is for
factory use only.)
5. Exit Installer Setup.
a. Press the ▲ key to save all changes and return
to normal operation.
Table 2. Heating Cycle Rate
aHigh efficiency furnace (90+).
bRefer to the equipment manufacturer’s instructions.
M2021
6
M2021
5
M2021
7
M2021
8
M12589
A
System Cycles Per Hour
Steam, gravity 1
Hydronic heat, condensing gas
furnacesa
3
Gas or oil forced air 6
Electric heat 9
Special applicationsb4, 5, 12
M12588
A
M1469
1
M1469
2
M12590A
PM