Heating will not come on (Cont). ■If temperature setting is higher than the current
temperature and displays HEAT, contact Honeywell
Customer Assistance at 1-800-468-1502.
Cooling will not come on. ■Check that the green LED is lit.
■Check that the switch on the thermostat is set to COOL.
■Check the system fuse or circuit breaker and replace
or reset, if necessary.
■The thermostat has a built-in time delay on cooling.
Allow five to ten minutes after changing the setting
before the air conditioner starts.
■If temperature setting is lower than current tempera-
ture and displays COOL, move the system switch
from COOL to OFF for ten minutes. After ten minutes,
return the switch to the COOL position. If the air
conditioner comes on, the compressor could have
reached its high limit temperature protection and shut
down. If the air conditioner does not come on after the