LOST COMMUNICATION

If the main unit display line for the remote sensor reading goes blank, press and hold DOWN ( ) button for 2 seconds to begin a new signal search. If the signal still isn’t received, make sure that remote sensor is in its proper location:

The distance between main unit and remote sensor is not over 100 feet (30meters).

The path between units is clear of obstacles. Reduce the distance as necessary.

Fresh batteries are installed correctly in both units.

If there is no reception, please perform the following steps:

Bring the main unit and remote sensor close together.

Remove four (4) small screws from the back of the remote sensor with small Phillips screwdriver, and open the battery compartment.

Remove the batteries from the battery compartment and reinstall them in the same manner. Remote sensor LED indicator will flash showing transmission of the signal.

Remove the batteries from the main unit and reinstall them in the same manner.

The remote temperature appeared on the main unit’s display will show that transmission is being received successfully.

CALENDAR AND CLOCK DISPLAY MODES Date is displayed in month-date or date-month format. Each press of the MODE button will change the clock display setting between the time of day with seconds, time of day with the day of the week and a calendar.

13

MANUAL SETTINGS

CLOCK

Press and hold MODE button for 3 seconds: the year digits will flash.

Press UP () or DOWN () to change flashing digits.

After the first value is set, press MODE button again to confirm.

Continue setting month, date, time display format, 12 or 24 hour time format, hour, minute, day of the week display language, time zone and Fahrenheit or Celsius display.

Press MODE for the last time to return to the default mode (time of day with seconds) after the last parameter is set.

ALARMS

(W)Weekly Alarm

The alarm will sound and the alarm icon will flash at the set time Mondays through Fridays.

(S)Single Day Alarm

The alarm will sound and the alarm icon will flash at the set time, but will not activate on subsequent days.

(PRE-AL)Low Temperature Pre-Alarm for remote location If the remote temperature reaches 32ºF (0ºC) or below, the pre-alarm feature will be activated. The pre-alarm time interval can be set for 15, 30, 45, 60 or 90 minutes earlier than the day of the week or single alarm time. Press and hold ALARM button for two seconds in Pre- Alarm mode to set the pre-alarm interval.

W (Weekly alarm), S (Single day alarm), and PRE-AL(Pre-alarm) icons will indicate which alarm mode is armed. You can enable or disable an alarm by pressing the UP () or DOWN () buttons in the selected alarm display mode. Press ALARM button to toggle between alarm modes or to return to the default display.

14

SETTING THE ALARM

To set any alarm,

Press ALARM button once to display alarm time. If the alarm is off, OFF will be displayed.

Press and hold ALARM button for two seconds. The hour digit will flash.

Enter the hour using DOWN ( ) or UP ().

Press ALARM button again. The minute digits will flash.

Enter the minutes using DOWN () or UP ( ).

Press ALARM button again to exit.

Repeat the same procedure to set a Single and Pre- Alarm.

SNOOZE

When the alarm sounds, press the SNOOZE button to temporarily stop the alarm. After the SNOOZE is depressed, the alarm sound will resume in five (5) minutes. If the alarm is not disabled after that, it will sound for four (4) more minutes and then will stop by itself.

DISABLING ALARM

Press ALARM button on the main unit to disable any of the alarms. When Weekly, Daily or Pre-Alarm is disabled, an applicable icon W, S, or Pre-Alwill disappear from the main unit’s display.

PRECAUTIONS

This product is engineered to give you years of satisfactory service if handled carefully. Here are a few precautions:

Do not immerse the units in water.

Do not clean the units with abrasive or corrosive materials. They may scratch the plastic parts and corrode the electronic circuits.

Do not subject the product to excessive force, shock, dust, temperature, or humidity, which may result in malfunctions, shorter lifespan, damaged batteries, and damaged parts.

Do not tamper with the units internal components. Doing so will invalidate the warranty and may cause damage. These units contain no user-serviceable parts.

Use only fresh batteries. Do not mix new and old batteries.

Read the user's manual thoroughly before operating the units.

TRANSMISSION COLLISION

Signals from the other household devices such as wireless doorbells, home security systems, and entry control, may interfere with this product or cause temporary reception interruption. This is normal and will not affect the general performance of the product. The transmission and reception of the temperature readings will resume once the interference subsides.

15

16

Page 4
Image 4
Honeywell TE103NL user manual Clock, Alarms

TE103NL specifications

The Honeywell TE103NL is a state-of-the-art temperature and humidity sensor that boasts advanced features designed for both commercial and residential applications. This cutting-edge device not only assists in maintaining optimal indoor climate but also enhances energy efficiency and comfort levels in various settings.

One of the primary features of the TE103NL is its dual-sensor technology, which accurately measures both temperature and humidity levels. This allows for precise monitoring and regulation of HVAC systems, ensuring that spaces maintain ideal conditions. The device is equipped with a sensitive thermistor for temperature readings, with a range typically between -40°C to 70°C (-40°F to 158°F) and an accuracy of ±0.5°C. For humidity, the sensor measures in the range of 0% to 100% relative humidity with an accuracy of ±2% at standard conditions. This level of precision makes the TE103NL an excellent choice for applications where maintaining specific environmental conditions is crucial.

The TE103NL features a compact design which lends itself to easy installation. It can be mounted on a wall or in a variety of environments, making it versatile for different setups. Additionally, this sensor is designed for compatibility with many building automation systems, enabling seamless integration and offering users valuable data for informed decision-making regarding climate control.

In terms of connectivity, the Honeywell TE103NL supports various communication protocols, promoting interoperability with a wide range of devices. This allows users to connect the sensor to smart home systems or advanced HVAC controls, facilitating remote monitoring and management. The device is also equipped with a sophisticated algorithm that enhances signal processing, minimizing errors and ensuring reliable performance under diverse conditions.

The TE103NL's durable construction ensures longevity and reliability, making it suitable for both indoor and outdoor installations. Its robust housing protects it from environmental factors, allowing it to operate effectively in various climates. This durability is complemented by low power consumption, making it an energy-efficient choice.

In summary, the Honeywell TE103NL stands out for its precise measurement capabilities, versatile installation options, and robust connectivity features. By providing users with accurate temperature and humidity data, this sensor plays a significant role in optimizing comfort and operational efficiency in a wide range of settings.