SNOOZE

When the time alarm sounds, press the SNOOZE/LIGHT button to temporarily stop it. After the SNOOZE/LIGHT is depressed, the time alarm sound will resume in four minutes. If the alarm is not disabled after that, it will sound for two more minutes and then will stop by itself.

BACKLIGHT

The backlight feature is enabled only after the time is set. To activate the backlight press the SNOOZE/LIGHT button once, and both – clock and weather station displays - will light up for five seconds.

PRECAUTIONS

This product is engineered to give you years of satisfactory service if handled carefully. Here are a few precautions:

Do not immerse the units in water.

Do not clean the units with abrasive or corrosive materials. They may scratch the plastic parts and corrode the electronic circuits.

Do not subject the product to excessive force, shock, dust, temperature, or humidity, which may result in malfunctions, shorter lifespan, damaged batteries, and damaged parts.

Do not tamper with the units internal components. Doing so will invalidate the warranty and may cause damage. These units contain no user-serviceable parts.

Use only fresh batteries. Do not mix new and old batteries.

Read the user's manual thoroughly before operating the units.

17

TROUBLESHOOTING

Check here before contacting customer service.

Issue

Symptom

Solution

Main unit

US Atomic Time

Place unit by the

 

signal is not received

window and keep it

 

 

there overnight

Remote sensor

Cannot locate remote

Check batteries

 

sensor

Check location

 

 

Press and hold DOWN

 

 

( ) button on the main

 

 

unit to search for the

 

 

signal form the remote

 

 

sensor

 

Cannot change the

Press "RESET" after

 

channel

setting the channel

 

Cannot change the ºC

Press "RESET" after

 

to ºF and back

setting ºC/ºF

 

Data does not match

Initiate manual sensor

 

data on the main unit

search (Press and hold

 

 

DOWN ( ) button on

 

 

the main unit)

18

SPECIFICATIONS

 

 

Power

Main Unit

 

 

Main unit: 2 AA size (UM-3) 1.5V batteries (not included)

Indoor Temperature

: 23.0°F to 122.0°F

Remote Sensor: 2 AAA size 1.5V batteries (not included)

Proposed operating range

Dimensions

Temperature resolution

(-5°C to +50°C)

Main unit: 3.5(L) x 7.09(H) x 1.18(D) inches

: 0.2°F (0.1°C)

 

Remote sensor: 2.35(L) x 3.77(H) x 0.86(D) inches

User-selectable (°F or °C) temperature display

 

 

 

 

Weather Forecast in five large graphic icons: Sunny, Partly

FCC STATEMENT

Cloudy, Cloudy, Rainy and Snowy

 

 

 

 

This device complies with Part 15 of the FCC Rules.

Maximum number of remote sensors

: 3 (one included)

Operation is subject to the following two conditions: (1)

Readings update interval

: every 45 seconds

EL backlight

 

 

This device may not cause harmful interference, and (2)

Low battery indicators – for each remote channel and main unit

This device must accept any interference received, including

Clock

 

 

interference that may cause undesired operation.

Precise atomic time

 

 

Warning: Changes or modification to this unit not expressly

4 US Time Zones

 

 

approved by the party responsible for compliance could

12/24 hour time format

 

 

void the user’s authority to operate the equipment.

Crescendo 4 minutes alarm with 5 minutes snooze

 

NOTE: This equipment had been tested and found to comply

Remote Sensor

 

 

with the limits for a Class B Digital device, pursuant to

Remote Temperature

 

 

Part 15 of the FCC Rules. These limits are designed to

Proposed operating range with alkaline

: -4°F to + 158°F

provide reasonable protection against harmful interference

batteries

in a residential installation. This equipment, installed and

 

(-20°C to + 70°C)

Proposed operating range with lithium

used in accordance with the instructions, may cause harmful

 

 

°

°

interference to radio communications.

batteries

: -38.8 F to +158 F

There is no guarantee that interference will not occur in a

 

°

°

Temperature resolution

(-38.8 C to + 70 C)

particular installation. If this equipment does cause harmful

: 0.1°C/0.2°F

 

RF Transmission Frequency

: 433 MHz

 

interference to radio or television reception, which can be

RF range

: Maximum 328

determined by turning the equipment off and on, the user is

Temperature transmission cycle

feet (100 meters)

encouraged to improve or correct turning the interference

: approximately

by one or more of the following measures:

Low battery indicator

45 seconds

 

Reorient or relocate the receiving antenna

 

 

Wall-mount of Table stand

 

 

• Increase the separation between the equipment and receiver.

 

 

 

Connect the equipment to an outlet on a circuit different

 

 

 

from that to which the receiver is connected.

 

 

 

Consult the dealer or an experienced radio / TV technician

 

 

 

 

for help.

19

 

 

 

20

 

 

 

 

 

Page 5
Image 5