TZ-4 TOTALZONE® ZONE CONTROL PANEL

68-0259-1 12

Fig. 17. Wiring single-stage heat pump with auxiliary heat.Fig. 18. Wiring single-stage heat pump with separate auxiliary and emergency heat.Two-speed Compressor: Wire the first stage compressor to Y1 and the second stage compressor to Y2.If the same heat source is used for auxiliary heat and emergency heat:— Wire a jumper from W3/AUX (auxiliary heat) to W1/E (emergency heat), see Fig. 19.If auxiliary heat is separate from emergency heat:— Wire the auxiliary heat to W3/AUX.— Wire emergency heat to W1/E, see Fig.20.Fig. 19. Wiring two-stage heat pump with auxiliary heat.Fig. 20. Wiring two-stage heat pump with separate auxiliary and emergency heat.Dual Fuel Heat Pumps: Install C7089B1000 Outdoor Temperature Sensor to terminals OT and OT.— Set outdoor sensor setting to: Balance point temperature of heat pump or Outdoor temperature above which the heat pump is to be used and below which the fossil fuel is to be used. — Set DIP switch number 5-8 to off for dual fuel operation. — Connect compressor to Y1. See Fig. 21.— Connect fossil fuel heat to W1/E. Connect second stage of fossil fuel to W3/AUX. Connect second stage of compressor to Y2. See Fig. 22.
M20521B
HVAC Equipment
RH
RC
W1/E
W2
W3/AUX
Single Transformer Heating/Cooling
systems require a jumper to be installed
connecting RH and RC
(factory installed).
Y1
Y2
G
O/B
Heating Transformer
24 VAC
Equip.Cooling Transformer
Auxiliary Heat
Compressor
Reversing Valve
Fan Relay
1
1
FIELD INSTALLED JUMPER.
M20522B
HVAC Equipment
R
H
R
C
W
1
/E
W
2
W
3
/AUX
Single Transformer Heating/Cooling
systems require a jumper to be installed
connecting R
H
and R
C
(factory installed).
Y
1
Y
2
G
O/B
Heating Transformer
24 VAC
Equip.Cooling Transformer
Emergency Heat
Auxiliary Heat
Compressor
Reversing Valve
Fan Relay
1FIELD INSTALLED JUMPER.
1
M20523B
HVAC Equipment
RH
RC
W1/E
W2
W3/AUX
Single Transformer Heating/Cooling
systems require a jumper to be installed
connecting RH and RC
(factory installed).
Y1
Y2
G
O/B
Heating Transformer
24 VAC
Equip.Cooling Transformer
Auxiliary Heat
First Stage Compressor
Second Stage Compressor
Reversing Valve
Fan Relay
1
1
FIELD INSTALLED JUMPER.
M20524
A
HVAC Equipment
R
H
R
C
W
1
/E
W
2
W
3
/AUX
Single Transformer Heating/Cooling
systems require a jumper to be installed
connecting R
H
and R
C
(factory installed).
Y
1
Y
2
G
O/B
Heating Transformer
24 VAC
Equip.Cooling Transformer
Emergency Heat
Auxiliary Heat
First Stage Compressor
Second Stage Compressor
Reversing Valve
Fan Relay