V2652 - OPTIMAL-PLUS

Function

The orifice between valve seat and valve cartridge increases when the valve is opened by turning the handwheel anti-clock- wise. More heating water can flow into the radiator or heat exchanger and the room temperature rises.

The orifice between valve seat and valve cartridge decreases when the valve is closed by turning the handwheel clockwise and the supply of heating water into the radiator or heat exchanger is throttled. At the right limit stop the valve is closed except for a possible leakage rate.

Please Note:

To avoid stone deposit and corrosion the composition of the medium should conform with VDI-Guideline 2035

Additives have to be suitable for EPDM sealings

System has to be flushed thoroughly before initial operation with all valves fully open

Any complaints or costs resulting from non-compliance with above rules will not be accepted by Honeywell

Please contact us if you should have any special require- ments or needs

Dimensions and Ordering Information

 

 

Fig. 1. Angle

 

 

 

 

 

 

Fig. 2. Straight

 

 

 

 

Table 1. Dimensions and OS-Nos. (OS=Order Specification)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

Pipe

 

kvs(cv)-

 

 

 

 

 

 

 

 

 

DN

 

connec-

 

l1

l2

l3

l4

 

l5

 

OS-No.

 

 

 

value

 

 

 

 

 

tion

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Angle (Fig. 1)

10

 

Rp 3/8"

 

2.1

(2.46)

26

52

 

22

 

V2652E0010

 

15

 

Rp 1/2"

 

2.3

(2.69)

29

58

 

26

 

V2652E0015

 

20

 

Rp 3/4"

 

2.7

(3.16)

34

66

 

29

 

V2652E0020

Straight (Fig. 2)

10

 

Rp 3/4"

 

1.7

(1.99)

59

85

 

 

V2652D0010

 

15

 

Rp 1/2"

 

1.8

(2.11)

66

95

 

 

V2652D0015

 

20

 

Rp 3/4"

 

2.2

(2.57)

74

106

 

 

V2652D0020

NOTE: All dimensions in mm unless stated otherwise.

EN0H-2119GE25 R1106

2

Honeywell y Subject to change

Page 2
Image 2
Honeywell V2652 specifications Function, Dimensions and Ordering Information