V4943/V8943B,C,N; V4944/V8944B,C,L,N REGULATING DIAPHRAGM GAS VALVES
65-0214—08 2
ORDERING INFORMATIONWhen purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further information,
or would like to comment on our products or services, please write or phone:
1. Your local Honeywell Environmental and Combustion Controls Sales Office (check white pages of your phone directory).
2. Honeywell Customer Care
1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386
3. http://customer.honeywell.com or http://customer.honeywell.ca
International Sales and Service Offices in all principal cities of the world. Manufacturing in Belgium, Canada, China, Czech
Republic, Germany, Hungary, Italy, Mexico, Netherlands, United Kingdom, and United States.
SPECIFICATIONSModels:
All models are solenoid-operated regulating diaphragm gas
valves. Details are shown in Table 1.
Table 1. Model Availability.
aIncludes natural gas, mixed air-natural gas, LP gas-air.
Flow Capacity: See Table 2.
Table 2. V4/8943 and V4/8944 Flow Capacity.
Valve Pattern:Straight-through, non offset.
Valve Body Material:Die-cast aluminum.
Electrical Terminations:1/4 in. (6 mm) spade terminals
(quick connects). Leadwires and cover for electrical conduit
connections are provided.
Valve Closing Time: On power failure, a maximum of
2 seconds at 7 in. wc inlet pressure.
Ambient Temperature Ratings: -40°F to +150°F (-40°C to
+66°C).
Maximum Fluid Temperatures: 150°F (66°C).
Model
Volt ag e
and
Frequency
Maximum
Current
Power
Consumption
(VA
Maximum)
Pipe Size
(in.)
Thread
Type
Maximum
Operating
Pressure Opening
Time
(sec.)
Pressure
Regulation
Type o f
Gas
Number
of Lead-
wirespsi kPa
V4943B 120V
(+10%,
-15%),
60 Hz
0.055A 6.6 1, 1-1/4,
1-1/2, 2
NPT 0.5 3.4 3 to 25 Single
stage Naturala2
V4943N 1, 1-1/4,
1-1/2
<6
V8943B 24V,(+10%,
-15%)
50/60 Hz
0.363A 9.0 1, 1-1/4,
1-1/2, 2
3 to 25
V8943C 1, 1-1/4 LP
V8943N 1, 1-1/4,
1-1/2
<6 Naturala
V4944B 120V
(+10%,
-15%)
60 Hz
0.077A 9.0 3 to 25 Two stage 3
V4944C LP
V4944L 1-1/4 <6
V4944N 1, 1-1/4,
1-1/2, 2 Naturala
V8944B 24V
(+10%,
-15%)
50/60 hz
0.470A 11.3 3 to 25
V8944C 1, 1-1/4,
1-1/2
LP
V8944L 1, 1-1/4 <6
V8944N 1, 1-1/4,
1-1/2, 2 Naturala
Pipe Size
(in.)
CSA
Certified
1.0 in. pd
Natural
Gas cfh
Btuh per
1000 cfh
Natural
gas
Regulation Capacities
0.64 sp gr Natural Gas
Maximum
cfh
Minimum
cfh
1 1,000 1,000,000 1,000 300
1-1/4 1,600 1,600,000 1,600 480
1-1/2 2,300 2,300,000 2,300 780
2 3,000 3,000,000 3,000 870