– 10 –
About The Keypads (Cont’d)
FIXED-WORD DISPLAY KEYPAD
AWAY: All burglary zones, interior and
perimeter, are armed.
STAY: Perimeter burglary zones, such as
protected windows and doors, ar e
armed.
NIGHT-STAY: NIGHT and STAY indicators both
light when perimeter burglary
zones plus pre-selected interior
zones (set by the installer) are
armed.
INSTANT: Entry delay is turned off:
Lit w ith STA Y = Ins tan t mode
Lit with AWAY = Maximum mode
ALARM
FIRE
AWAY
BYPASS
STAY
CHECK INSTANT CANCELED
NIGHT NO AC
NOT READY
CHIME BAT
PHONE TEST
6150disp
FIXED-WORD DISPLAY
BYPASS: This appears when one or more burg lary protection zones have been
bypassed.
NOT READY: Appears when burglary portion of the system is not ready for arming (due
to open protection zones). The sys tem is ready to arm when this message
disappears and the READY indicator light comes on.
NO AC: Appears when AC power has been cut off. Sy stem is operating on backup
battery power.
AC: Appears when AC power is present.
CHIME: Appears when the chime featur e is activated.
BAT: Low battery c ondition in a wireless sensor (if zone number display ed) or
low system battery (if no zone number disp layed).
ALARM: Appears w hen an intrusion has been detected an d the system is armed
(also appears during a fire alarm or audible emergency alarm).
Accompanied by the protection zone in alarm.
CHECK: Appears when a malfunction is discov ered in the system at any time, or if
an open is detected in a fire zone at any time, or a fault in a DAY/NIGHT
burglary zone during a disarmed period. Accompanied by a display of
zone number in trouble.
FIRE: Appears when a fire alarm is generated. Accompanied by a disp lay of the
zone in alarm.
A FIRE display also appears when a fire alarm is manually activated,
accompanied by a display of the fire emergency key zone number.
CANCELED: Appears when an alarm has b een silenced by the Code + OFF sequence
and will remain on until another Code + OFF sequence i s keyed.