INSTALLATION INSTRUCTIONS
®U.S. Registered Trademark
Copyright © 1998 Honeywell Inc. • All Rights Reserved
69-0668-1
VR8300A Continuous Pilot CombinationGas ControlAPPLICATION
These continuous pilot gas controls are used in gas-fired
appliances with capacities up to 200 cfh at 1 in. wc
pressure drop (5.7 cmh at 0.25 kPa) on natural gas.
Included are a manual valve, safety shutoff, two automatic
operators, and a pressure regulator. See Table 2 for
temperature range and regulator type.
The VR8300 setup for natural gas includes a 39369 LP
Conversion Kit. The kit contains a new cap screw, a
pressure regulator adjustment screw, a tapered spring and
a conversion label. The control must be equipped with a
standard servo pressure regulator. Step-opening gas
controls cannot be converted.
Body Pattern:
Straight-through body pattern.
Inlet x Outlet Sizes Available:
1/2 x 1/2 in., 1/2 x 3/4 in., and 3/4 x 3/4 in. (factory-installed
inlet flange).
Adapters:
Adapters available for 1/2 and 3/4 in. straight and angle
connections. Refer to Table 3.
Electrical Ratings:
Voltage and Frequency: 24 Vac, 50/60 Hz.
Current Draw: 0.70A.
Capacity:
aCapacity based on 1000 Btu/cu ft, 0.64 specific gravity natural gas at 1 in. wc pressure drop (37.3 MJ/cu m, 0.64 specific
gravity natural gas at 0.25 kPa pressure drop).
Use conversion factors in Table 1 to convert capacities for
other gases.
Table 1. Gas Capacity Conversion Factors.
Gas Specific
Gravity Multiply Listed
Capacity By
Manufactured 0.60 0.516
Mixed 0.70 0.765
Propane 1.53 1.62
Table 2. Temperature Range and Regulator Type.
Table 3. Flange Part Numbers.
Part Number
Inlet/Outlet
Pipe Size Flange
Type Without Hex
Wrench With Hex
Wrench
1/2 in. NPT Straight 393690-6 393690-16
Elbow 393690-3 393690-13
3/4 in. NPT Straight 393690-4 393690-14
Elbow 393690-5 393690-15
NOTE: Flange kits include one flange with attached
O-ring and fan mounting screw.
Approvals:
International Approval Services Listed: L2025007.
Australian Gas Association Certificate: Applied for.
Delta C: Pending approval.
Size (Inlet x Outlet) Capacity at 1 in. wc
Pressure Drop
a
Minimum Regulated
Capacity Maximum Regulated
Capacity
1/2 in. x 1/2 in. 180 cfh (5.1 cmh) 30 cfh (0.8 cmh) 225 cfh (6.4 cmh)
1/2 in. x 3/4 in. 190 cfh (5.4 cmh) 30 cfh 0.8 cmh) 290 cfh (8.2 cmh)
3/4 in. x 3/4 in. 200 cfh (5.7 cmh) 30 cfh (0.8 cmh) 300 cfh (8.5 cmh)
Model Ambient
Temperature Range
Regulator
Number °F°CType
VR8300A 0° to 175°18° to 79°Standard-opening