This Hoover Cleaning Performance System is for comparing the relative pro- gressive performance of Hoover uprights only and not for comparison with any other brands. The majority of this rating is based upon the ASTM International Carpet Cleaning Effectiveness Testing (ASTM Test F608). Other performance factors include Hose Power (ASTM Test F558), Surface Litter Cleaning, Hard Floor Cleaning, Edge Cleaning, Cleaning Width and Air Filtration.

4. Trouble shooting

If a minor problem occurs, it usually can be solved quite easily when the cause is found by using the checklist below.

Problem: Cleaner won’t run

Possible Cause

Possible Solution

Not firmly plugged in

Plug unit in firmly

No voltage in wall plug

Check fuse or breaker

Blown fuse or tripped breaker

Replace fuse or reset breaker

Thermal protector activated

Allow cleaner to cool for 30 minutes (this will reset the thermal protector)

Problem: Cleaner / tools won’t pick up

Possible Cause

Possible Solution

Broken or worn belt(s)

Replace belt(s)

Brush roll worn

Replace brush roll

Filter bag full

Change filter bag

Incorrect carpet height setting

Move carpet height control to lower setting

Blockage in air flow passage

Clear blockage (see “Clearing block- ages section)

Problem: Cleaner hard to push

Possible Cause

Possible Solution

Incorrect carpet height setting

Move carpet height control to a higher setting

Problem: Cleaner won’t self-propel

Possible Cause

Possible Solution

Flat belt broken or worn

Replace belt

Self-propel button in OFF position

Slide button to ON

Problem: Brush roll not turning

Possible Cause

Possible Solution

Brush roll in OFF position

Move brush roll control to ON position (carpet)

Flat belt broken or worn

Replace belt

Clearing blockages

Disconnect cleaner from electri- cal outlet.

Warning - Brush roll can start suddenly. Unplug cleaner when it is turned over.

Low suction or pick up may be due to a blockage in the system. Refer to the following steps to check for blockages continuing with each step until the blockage is found:

1.Check fullness of filter bag; change if needed.

4-1

C

A

B

Checking airflow path

2.Plug cleaner in and turn ON. Check for suction at end of hose (A).

a.If there is suction, continue with step 3.

b.If there is no suction, check for blockage in hose and dirt tube as follows:

1)Disconnect hose from dirt duct (C) by reversing procedure for “Attach hose”, Figs. 1-5 and 1-6.

2)Clear out hose.

3)Look into (C) and remove blockage.

3.Check connection at hose tube (B); remove any blockage.

4.Turn cleaner OFF and unplug.

4-2

F

H

G

Checking under bottom plate

5.Remove bottom plate (Fig. 3-9) and brush roll (Fig. 3-15).

Look into opening (F), in channnels (G) and around liner (H), and remove any accumulated debris.