Hotpoint G310 Electrical Connection, User Characteristics, Type, Pressure, Burner, O Injectors

Models: G310 G320X

1 12
Download 12 pages 47.18 Kb
Page 9
Image 9
Electrical Connection

Electrical Connection

Electrical Connection

THIS APPLIANCE MUST BE EARTHED.

The installation procedure must be carried out by a qualified electrician.

The electrical safety of this appliance is guaranteed only if the appliance is correctly earthed in compliance with the standards of electrical safety.

The manufacturer can under no circumstances be considered responsible for any damage that might occur due to incorrect earthing of the hob.

IMPORTANT POINTS:

Your hob is supplied with a special connection cable.

If ever the cable is damaged it should be replaced by an authorised service engineer only.

Disconnect the hob form the electrical supply before any work is carried out.

Connecting the supply cord to the electrical mains: The hob must be connected to a double pole mains switch which must be installed between the appliance and the mains. The double pole mains switch must have a minimum of 3mm of space between the contacts, be sized to the load and comply with current regulations (the switch must not be able to disconnect the earth conductor).

The supply cord should conform to BS6004 conductor size 4mm2 and must be positioned so that no part of it reaches a temperature of 50°C higher than room temperature.

Before making the connection, make sure that:

the limiter switch (fuse) and the residual wiring can support the appliance load (see the rating plate, below).

the mains system is properly earthed in compliance with current regulations and provisions.

there is easy access to the socket or the double pole mains switch after the appliance is installed.

the isolation switch must not be positioned directly above the hob.

IMPORTANT:

If the hob is installed above a built-in oven, the electrical connection for the hob must be independent of that for the oven, both for safety reasons and to facilitate the removal of the oven for maintenance, repair etc.

User Characteristics

TYPE

PRESSURE

BURNER

O INJECTORS

CAPACITY

CONSUMPTION

 

 

 

 

 

 

 

Natural Gas

G20

20

Rapid

116

3000W

286l/h

 

mbar

Auxilliary

79

1000W

95l/h

 

 

 

Wok

137

3600W

343l/h

 

 

 

 

 

 

 

LPG

G30/31

28-30/37

 

 

 

 

 

mbar

Rapid

86

3000W

218l/h

 

 

 

 

 

 

Auxilliary

50

1000W

73l/h

 

 

 

 

 

 

 

 

Wok

94

3600W

262l/h

 

 

 

 

 

9

Page 9
Image 9
Hotpoint G310 Electrical Connection, User Characteristics, Type, Pressure, Burner, O Injectors, Capacity, Consumption