Hotpoint G750, G760 operating instructions Setting the burners to minimum

Models: G760 G750

1 16
Download 16 pages 50.63 Kb
Page 4
Image 4
•Setting the burners to minimum:

4. Once this procedure is finished, replace the old rating

GB sticker with one indicating the new type of gas used. Sticker are available from any of our Service Centres.

Replacing the nozzles on separate “double flame “ burners:

1.remove the grids and slide the burners from their housings. The burner consists of 2 separate parts (see figure);

2.unscrew the burers with a 7 mm wrench spanner. The internal burner has a nozzle, the external burner has two (of the same size). Replace the nozzle with models suited to the new type of gas (see table 1).

3.replace all the components by repeating the steps in reverse order.

Adjusting the burners’ primary air : Does not require adjusting.

Setting the burners to minimum:

1.Turn the tap to the low flame position.

2.Remove the knob and adjust the adjustment screw, which is positioned in or next to the tap pin, until the flame is small but steady.

3.Having adjusted the flame to the required low setting, while the burner is alight, quickly change the position of the knob from minimum to maximum and vice versa several times, checking that the flame does not go out.

4.Some appliances have a safety device (thermocouple) fitted. If the device fails to work when the burners are set to the low flame setting, increase this low flame setting using the adjusting screw.

5.Once the adjustment has been made, replace the seals on the by-passes using sealing wax or a similar

substance.

!If the appliance is connected to liquid gas, the regulation screw must be fastened as tightly as possible.

!Once this procedure is finished, replace the old rating sticker with one indicating the new type of gas used. Stickers are available from any of our Service Centres.

!Should the gas pressure used be different (or vary slightly) from the recommended pressure, a suitable pressure regulator must be fitted to the inlet pipe (in order to comply with current national regulations).

DATA PLATE

Electrical

see data plate

connections

This appliance conforms to the following

European Economic Community directives:

-2006/95/EEC dated 12/12/06 (Low Voltage) and subsequent amendments

-2004/108/EEC dated 15/12/04 (Electromagnetic Compatibility) and subsequent amendments

-93/68/EEC dated 22/07/93 and

subsequent amendments.

- 2009/142/EEC dated 30/11/09 (Gas) and subsequent amendments.

- 2002/96/EC and subsequent amendments.

4

Page 4
Image 4
Hotpoint G750, G760 operating instructions Setting the burners to minimum