Hotpoint GE760RX manual Characteristic of the burners and nozzles, Minimum Regulation, Liquid Gas

Models: GE760RX GF760RX

1 16
Download 16 pages 39.76 Kb
Page 9
Image 9
Adapting the hob for DifferentTypes of Gas

Adapting the hob for DifferentTypes of Gas

To adapt the hob to a different type of gas than that for which it was designed, (see the sticker under the hob or on the packaging), the burner nozzles must be changed, as follows:

Remove the pan supports and slide the burners out of the cooktop.

Unscrew the nozzles using a 7mm socket wrench and replace them with those for the new type of gas. (See table 1, “Burner and Nozzle Specifications”).

Reassemble the parts following the instructions in reverse order.

On completing the operation, replace the old rating label

with the one showing the new type of gas; the sticker is available from our Service Centre.

If the gas pressure is different than that prescribed, a pressure regulator must be installed at the source, in compliance with national standards governing the use of piped gas regulators.

Regulation of Air Supply to the Burner

The burners do not need a primary air regulator.

Minimum Regulation

Turn the gas valve to minimum.

Remove the knob and turn the regulator screw (positioned

either on the side of the top or inside the shaft) clockwise until the flame becomes small but regular.

N.B.: In the case of liquid gas, the regulation screw must be fully screwed in (clockwise).

Make sure that, when the knob is turned rapidly from high to low, the flame does not go out.

In the event of a malfunction on appliances with the

security device (thermocouple) when the gas supply is set at minimum, increase the minimum supply levels using the regulator screw.

Once the adjustment has been made, apply sealing wax, or a suitable substitute, to the old seals on the by-pass.

Characteristic of the burners and nozzles

Table 1

 

 

 

 

 

Liquid Gas

 

 

Natural Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Diameter

Thermal power

By-Pass

Nozzle

 

Flow*

Nozzle

 

Flow*

 

(mm)

kW (p.c.s.*)

1/100

1/100

 

g/h

1/100

 

l/h

 

 

Nomin.

 

Ridot.

(mm)

(mm)

***

 

**

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fast (R)

100

3,00

 

0,70

41

86

218

 

214

116

 

286

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi Fast (S)

75

1,90

 

0,40

30

70

138

 

136

106

 

181

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary (A)

55

1,00

 

0,40

30

50

73

 

71

79

 

95

 

 

 

 

 

 

 

 

 

 

 

 

 

Triple Crown (TC)

100

2,50

 

0,80

48

83

182

 

179

124

 

238

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply

Nominal (mbar)

 

 

28-30

 

37

 

20

Minimum (mbar)

 

 

20

 

25

 

17

Pressures

 

 

 

 

Maximum (mbar)

 

 

35

 

45

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*At 15°C and 1013 mbar-dry gas

**Propane P.C.S. = 50.37 MJ/kg.

***Butane P.C.S. = 49.47 MJ/kg. Natural P.C.S. = 37.78 MJ/m3

9

Page 9
Image 9