Hotpoint HE91, HE61 manual Mounting the hood body, Connections, Ducted Version Air Exhaust System

Models: HE91 HE61

1 16
Download 16 pages 6.37 Kb
Page 7
Image 7
Mounting the hood body

Mounting the hood body

Screw the two screws 12d supplied onto the brackets 7.1

Hook the hood body onto bracket 7.1, centring it around the vertical line.

Using the adjusting screws 12d underneath the hood to level the hood body.

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer.

To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet.

Fix the pipe in position using sufficient pipe clamps (not supplied).

Remove any activated charcoal filters.

Side air exhaust on ducted version (connection to exhaust flue above wall cupboards).

Assemble the half-shells of the hood body extension piece 14.

Push fit the assembled hood body extension 14 onto the air exhaust outlet.

Insert the deflector 16 into the air exhaust fitting 15 to close off the unused outlet.

Push fit connection piece 15 to the hood body extension piece 14, ensuring that the free end matches up with the required opening in the chimney.

Remove any activated charcoal filters.

RECIRCULATION VERSION AIR OUTLET

Push fit the air outlet fitting 15 onto the air outlet of the hood body.

The air outlet directional grills must be fitter after the lower outlet duct has been installed.

Ensure that the activated charcoal filters have been inserted.

GB

 

7

Page 7
Image 7
Hotpoint HE91 Mounting the hood body, Connections, Ducted Version Air Exhaust System, Recirculation Version Air Outlet