Grease/odour filter warnings

The bar at the top left flashes to indicate that the grease filter is saturated.

The bar at the top right flashes to indicate that the odour filter is saturated.

If both bars are flashing, then both filters are saturated.

You must then clean/replace the grease filter (A) or odour filter (B) or both, accordingly (see “Maintenance and care”). The latter only applies to the filter version.

To reset the filter counter:

Hold down T4 for three seconds while the hood is on.

If both filter warnings are active at the same time, you must reset each separately.

The first sequence resets the grease filter, while the second sequence resets the odour filter.

Configuring the hood

To set the operating mode of the hood, hold down T4 for 6 seconds. After a long beep, the type of installation displays:

Ducted

(square at bottom left flashing).

Filter

(square at bottom right flashing).

You can change the type of installation by pressing T4. To quit configuration mode, press T1 once; this switches the unit off and saves the last displayed setting.

Maintenance and care

Caution! Before cleaning or servicing the unit, disconnect it from the mains by pulling the power plug or disconnecting the main circuit breaker.

First cleaning

Remove the protective film

Clean with a damp sponge and a little neutral soap

Rinse off with a damp cloth

Dry with a soft cloth; if the hood is stainless steel, dry along the metal's grain

Periodic cleaning

The hood must be cleaned frequently (at least as often as GB you service the grease filter), inside and out. Use a damp cloth and a neutral liquid detergent with lukewarm water.

Do not use abrasive or corrosive products.

Warning: Failure to observe the hood cleaning and filter cleaning/replacement instructions can result in fires. Follow the instructions carefully. The manufacturer is not liable for any damage to the motor or fires caused by incorrect care or failure to follow the above instructions.

Servicing the grease filter (A)

 

The grease filter retains the

 

particles of grease produced

 

during cooking; it must be

 

cleaned at least once a month

 

with a non - aggressive

 

detergent, either by hand or

A

with a low temperature, short

dishwasher cycle.

 

 

To extract the grease filter,

 

pull the spring loaded handle.

If washed in a dishwasher, the metal filter may change colour, but this does not affect its performance.

Servicing the charcoal filter (B)

 

The charcoal filter retains

 

unpleasant cooking odours.

 

The filter saturates after a

 

variable time, depending on

 

the type of cooking and how

 

often the grease filter is

B

cleaned. The cartridge must

be replaced at least once

 

every twenty months.

 

This filter can NOT be washed

or regenerated

Disassembly: Rotate the filter 90° to remove it from the suction assembly.

Assembly: Fit the active-carbon filter into the suction assembly and rotate it 90° to secure it in place.

Replacing the bulbs

Disconnect the unit from the mains and remove the grease filter.

Caution! Make sure the bulbs are cool before touching them.

1. Extract the guard

by prising it out with a small flat head screwdriver or something similar.

2.Replace the faulty bulb.

Use only bulbs of the

same type (for details, see the technical data in the following manual).

3. Refit the guard (push it in).

PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24