Hotpoint GF641X Checking the tightness of the connection, Adapting to different types of gas

Models: GF640W GF640X GF641X KSG641X GF641 GF640K

1 16
Download 16 pages 48.66 Kb
Page 4
Image 4
Checking the tightness of the connection

Checking the tightness of the connection

GB

! When the installation process is complete, check

 

 

the pipe fittings for leaks using a soapy solution.

 

Never use a flame.

 

Adapting to different types of gas

 

To adapt the hob to a different type of gas other

 

than default type (indicated on the rating plate at the

 

base of the hob or on the packaging), the burner

 

nozzles should be replaced as follows:

 

1. Remove the hob grids and slide the burners off

 

their seats.

 

2. Unscrew the nozzles using a 7 mm socket

 

spanner, and replace them with nozzles for the

 

new type of gas (see table 1 “Burner and nozzle

 

characteristics”).

 

3. Reassemble the parts following the above

 

procedure in the reverse order.

 

4. Once this procedure is finished, replace the old

 

rating sticker with one indicating the new type of

 

gas used. Sticker are available from any of our

 

Service Centres.

Adjusting the burners’ primary air : Does not require adjusting.

Setting the burners to minimum:

1.Turn the tap to the low flame position.

2.Remove the knob and adjust the adjustment screw, which is positioned in or next to the tap pin, until the flame is small but steady.

3.Having adjusted the flame to the required low setting, while the burner is alight, quickly change the position of the knob from minimum to maximum and vice versa several times, checking that the flame does not go out.

4.Some appliances have a safety device (thermocouple) fitted. If the device fails to work when the burners are set to the low flame setting, increase this low flame setting using the adjusting screw.

5.Once the adjustment has been made, replace the seals on the by-passes using sealing wax or a similar substance.

!If the appliance is connected to liquid gas, the regulation screw must be fastened as tightly as possible.

!Once this procedure is finished, replace the old rating sticker with one indicating the new type of gas used. Stickers are available from any of our Service Centres.

!Should the gas pressure used be different (or vary slightly) from the recommended pressure, a suitable pressure regulator must be fitted to the inlet pipe (in order to comply with current national regulations).

DATA PLATE

Electrical

see data plate

connections

This appliance conforms to the following

European Economic Community directives:

-2006/95/EEC dated 12/12/06 (Low Voltage) and subsequent amendments

-2004/108/EEC dated 15/12/04 (Electromagnetic Compatibility) and subsequent amendments

-93/68/EEC dated 22/07/93 and

subsequent amendments.

- 2009/142/EEC dated 30/11/09 (Gas) and subsequent amendments.

- 2002/96/EC and subsequent amendments.

PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24