4-2. Optional Side Panel Controls

1

2

3

 

1

Preflow Control

 

4

Control sets time gas flows before

welding wire is energized. Time

 

 

range is 0 to 5 seconds.

 

 

2

Postflow Control

 

 

Control sets time gas flows after

 

completion of burnback.

Time

 

range is 0 to 5 seconds.

 

 

3

Spot Time Control

 

 

Factory set for 0.25 to 5 seconds of

 

spot time. Rotating knob fully

 

counterclockwise selects

an

 

untimed continuous weld.

 

 

4

Run-In Control

 

 

Use control to set wire feed speed

 

before arc initiation.

 

Close side door.

Ref. 802 357-A / Ref. 186 589 / 210 436-A

SECTION 5 − MAINTENANCE & TROUBLESHOOTING

5-1. Routine Maintenance

Y Disconnect power before maintaining.

3 Months

Replace

 

Repair Or

Clean And

 

Replace

Tighten

Unreadable

 

 

Cracked

Weld

Labels

 

 

Weld Cable

Terminals

 

 

 

 

 

Replace

 

 

 

Cracked

14-Pin Cord

Gun Cable

Gas Hose

Parts

 

 

 

6 Months

 

 

Clean

 

Blow Out Or Vacuum

 

 

Inside,

 

Drive

OR

 

During Heavy Service,

 

Rolls

 

 

Clean Monthly

 

 

 

OM-193 472 Page 17