HP ProLiant servers that support redundant power supplies only allow installation of same-type supplies. A power supply mismatch or an unsupported power supply will result in an error indication as described in Table 4.

Table 4: HP CS power supply compatibility with HP PDS

Condition

System insight

Description

display indication

 

 

 

 

 

Power supply

Power supply LED (all

 

mismatch detected

supplies) blinking

BIOS ROM will power up power supply #1 and then halt.

during boot

amber

 

 

 

 

Power supply

Power supply LED

iLO will detect the mismatch and not allow the added power supply to turn

mismatch detected

(added supply only)

on.

during runtime

blinking amber

 

 

 

 

Unsupported power

Power supply LED

BIOS ROM will detect an unsupported power supply installation. BIOS ROM

supply detected

(added supply only)

will halt at POST with a failure message and will light the appropriate LED.

during boot

blinking amber

The LED will reset when the unsupported supply has been removed and

 

 

system is restarted.

 

 

 

HP CS power supplies are hot-pluggable/hot-swappable on ProLiant servers under the following conditions:

The server must already be configured with redundant power supplies.

The removed and replacement power supplies must be of the same type (same part number).

For all other situations, the ProLiant server should be powered down before a power supply is removed or installed.

Conclusion

The common slot power supply bay allows over 90% of the ProLiant server line to use 80 PLUS-certified power supplies. By using IT equipment that supports common-slot power supplies, IT and facilities administrators can reduce spares inventory costs and space requirements while reducing energy consumption costs and reclaiming data center power capacity.

For more information

Visit the URLs listed below if you need additional information.

Resource description

Web address

 

 

HP Power Supplies

http://h18004.www1.hp.com/products/servers/rackandpower/pow

 

ersupplies/index.html

HP ProLiant servers

www.hp.com/go/proliant

 

 

HP ProLiant Energy Efficient Solutions

http://h71028.www7.hp.com/enterprise/cache/600307-0-0-0-

 

121.html

Automated Energy Optimization

http://h20195.www2.hp.com/V2/GetPDF.aspx/4AA3-9650ENW.pdf

 

 

HP Power Advisor utility

www.hp.com/go/hppoweradvisor

 

 

80 PLUS program

www.80plus.org

 

 

HP interactive online compatibility guide

www.hpproliantoptions.com/index.aspx

 

 

HP Intelligent Power Discovery (Power Discovery

www.hp.com/go/ipd

Services)

 

 

 

11