Reverse this procedure to install the heat sink.

NOTE: To properly ventilate the computer, allow at least a 7.6-cm (3-in) clearance on the left side of the computer.

The computer uses an electric fan for ventilation. The fan is controlled by a temperature sensor and is designed to turn on automatically when high temperature conditions exist. These conditions are affected by high external temperatures, system power consumption, power management/battery conservation configurations, battery fast charging, and software requirements. Exhaust air is displaced through the ventilation grill located on the left side of the computer.

Processor

NOTE: All processor spare part kits include replacement thermal material.

Description

Spare part number

 

 

Intel Core i7 processor, Quad Core

 

 

 

3612QM, 2.1-GHz processor with 6-MB L3 cache

680647-001

 

 

Intel Core i5 processors, Dual Core

 

 

 

3360M, 2.8-GHz processor with 3-MB L3 cache

681953-001

 

 

3320M, 2.6-GHz processor with 3-MB L3 cache

681952-001

 

 

2450M, 2.5-GHz processor with 3-MB L3 cache

676359-001

 

 

Intel Core i3 processors, Dual Core

 

 

 

3110M, 2.3-GHz processor with 3-MB L3 cache

682417-001

 

 

2370M, 2.4-GHz processor with 3-MB L3 cache

677152-001

 

 

2350M, 2.3-GHz processor with 3-MB L3 cache

653340-001

 

 

Intel Pentium processor, Dual Core

 

 

 

B980, 2.4-GHz, with 2-MB L3 cache

692428-001

 

 

66 Chapter 4 Removal and replacement procedures