QuickSpecs

Compaq 500B Microtower PC

System Details

Chassis

Front Panel

Power button

 

 

Power On LED

 

 

HDD Activity LED

 

Cooling Solutions

Power Supply Fan (variable speed)

 

Supported

Active heatsink (variable speed)

 

 

Chassis fan

 

Slots Supported

Four (4) full-height expansion slots

 

Front I/O

Two (2) USB 2.0 ports

 

Rear I/O

Standard Micro ATX I/O connectors, including four (4) USB 2.0 ports

 

Drive Bays

One (1) 5-1/4” external

 

 

One (1) 3-1/2” internal

 

Internal Speaker

N/A

 

Security

Padlock loop

 

 

Kensington Lock Support

 

 

Support for chassis padlocks and cable lock devices

 

Power Supply

300-watt ATX Power Supply – PFC/non-PFC with a 115v/230v line

 

 

switch (varies by country/region)

 

 

 

Unit Environment and Operating Conditions

General Unit Operating Guidelines

Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is operated within the specified operating range.

Leave a 4 in (10.2 cm) clearance on all vented sides of the computer to permit the required airflow.

Never restrict airflow into the computer by blocking any vents or air intakes.

Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-circulated or preheated air.

Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign matter can block the vents and limit the airflow.

If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the enclosure, and the same operating guidelines listed above will still apply.

Temperature Range

Operating

50° to 95° F (10° to 35° C)

 

Non-operating

–22° to 140° F (–30° to 60° C)

Relative Humidity

Operating

10% to 90% (non-condensing at ambient)

 

Non-operating

5% to 95% (non-condensing at ambient)

Maximum Altitude

Operating

10,000 ft (3048 m)

(unpressurized)

Non-operating

30,000 ft (9000 m)

NOTE:Operating temperature is de-rated 1.0 deg C per 1000 ft (300 m) to 10,000 ft (3000 m) above sea level, no direct sustained sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.

DA - 13418 Worldwide QuickSpecs — Version 2 — 10.30.2009

Page 7

Page 7
Image 7
HP 500B manual Chassis Front Panel, Cooling Solutions, Slots Supported, Front I/O, Rear I/O, Drive Bays, Power Supply