Configure and verify the host

Verifying configuration settings

Verify that all paths to the storage system are present with cfgadm -alcommand. To display the LUNs configured to each path, execute cfgadm -al-o show_FCP_dev as shown in the example below.

The following examples are with 4 paths (ports) visible from the array on the host and with 2 LUNs configured on the array for the host. You should normally see 4 paths with EVA3000/ EVA5000/ EVA4000/ EVA6000, however you might also see up to 8 paths with EVA8000.

1.Enter the cfgadm command to verify the paths to the LUNs (note that you need to have configured LUNs on the array for the host in order to see the “disk” lines):

Example: # cfgadm -al -o show_FCP_dev

Receptacle

Occupant

Condition

Ap_Id

Type

c2

fc-fabric

connected

unconfigured

unknown

c2::50001fe1002709f8,0

array-ctrl

connected

unconfigured

unknown

c2::50001fe1002709f8,1

disk

connected

unconfigured

unknown

c2::50001fe1002709f8,2

disk

connected

unconfigured

unknown

c2::50001fe1002709fc,0

array-ctrl

connected

unconfigured

unknown

c2::50001fe1002709fc,1

disk

connected

unconfigured

unknown

c2::50001fe1002709fc,2

disk

connected

unconfigured

unknown

c3

c-fabric

connected

unconfigured

unknown

c3::50001fe1002709f9,0

array-ctrl

connected

unconfigured

unknown

c3::50001fe1002709f9,1

disk

connected

unconfigured

unknown

c3::50001fe1002709f9,2

disk

connected

unconfigured

unknown

c3::50001fe1002709fd,0

array-ctrl

connected

unconfigured

unknown

c3::50001fe1002709fd,1

disk

connected

unconfigured

unknown

c3::50001fe1002709fd,2

disk

connected

unconfigured

unknown

With Solaris 8 or 9, the Occupant status will be displayed Solaris 10 (SPARC and x86), you will see a configured

as above in a SAN environment. With status.

2.For Solaris 8 and 9, use cfgadm -c configure c# command to configure the host to access the storage system as shown in the example below. The value of # is gathered from the output of the cfgadm -alpreviously executed.

Example:

#cfgadm -c configure c2

#cfgadm -c configure c3

3.Execute the cfgadm command to view configured devices. After the configuration, the following command will show the array controllers as configured:

#cfgadm -al

Ap_Id

Type

Receptacle

Occupant

Condition

c0

scsi-bus

connected

configured

unknown

c0::dsk/c0t0d0

disk

connected

configured

unknown

c0::dsk/c0t6d0

CD-ROM

connected

configured

unknown

c1

scsi-bus

connected

unconfigured

unknown

c2

fc-fabric

connected

configured

unknown

c2::50001fe1002709f8

array-ctrl

connected

configured

unknown

c2::50001fe1002709fc

array-ctrl

connected

configured

unknown

c3

fc-fabric

connected

configured

unknown

c3::50001fe1002709f9

array-ctrl

connected

configured

unknown

c3::50001fe1002709fd

array-ctrl

connected

configured

unknown

6