SCOTTY WOOD FURNACE – INSTRUCTION MANUAL

KERR SCOTTY Wood Furnace

Model DB-102

Certified by the Canadian Standards Association

Manufactured by: Parrsboro Metal Fabricators Ltd. P.O. Box 637, Crossroads 12118, Highway 209 Parrsboro, Nova Scotia, Canada B0M 1S0

SPECIFICATIONS

Length

 

46

1/2”

Width

 

22

1/2”

Height

 

43”

Shipping Weight

 

344 lb

Fire Box 1/8”plate

Length

27

1/2”

 

Diameter

18”

Secondary Heat Exchanger

14 gauge steel

Fire Box Door

Cast Iron

12” x 12”

Warm Air Plenum

 

29” x 20 3/4”

Return Air Plenum

 

14

½” x 20 3/4”

Air Filter Size

 

16” x 20” x 1”

Blower Size

 

G9 – 10

Blower Motor

 

1/4 hp

CFM

 

1000 (Required)

Smoke Pipe

 

7” Inside Diameter

Floor to smoke pipe center

36”

Output (max)

 

70,000 Btu/h

Fuel

 

Wood 24” logs

Electrical Rating

 

Volts 120, Cycles 60, Amps 15

NOTE – Keep this manual in a safe place for future reference. Follow manual carefully for the correct way to install and operate this unit.

CAUTION – Do not fire this unit until operating instructions have been read and fully understood.

INSTALL WOOD FURNACE ONLY ON A FURNACE DUCT SYSTEM AND CHIMNEY

THAT ARE IN GOOD CONDITION AND APPROVED FOR USE.

SAVE THESE INSTRUCTIONS

Scotty

3

Oct-06