The workaround involves renaming all the WINBOM.INI files (other than on the X:\ drive since WinPE boots to X:\) before running FACTORY.EXE, and then renaming all the other WINBOM.INI files back after FACTORY.EXE is finished as shown below. Please note that if something goes wrong before WINBOM.INI files are renamed to their original name, other utilities like HP Backup and Recovery Manager will not work.
for %%a in (a,b,c,d,e,f,g,h,i,j,k,l,m,n,o,p,q,r,s,t,u,v,w,y,z) DO if exist %%a:\winbom.ini ren %%a:\winbom.ini winbom.tmp
factory
for %%a in (a,b,c,d,e,f,g,h,i,j,k,l,m,n,o,p,q,r,s,t,u,v,w,y,z) DO if exist %%a:\winbom.ini ren %%a:\winbom.tmp winbom.ini
For performance reasons, the WINBOM.INI in HP Backup and Recovery Manager has the PageFileSize=64 line that creates the PAGEFILE.SYS on C:.
NOTE: After
Managing HP Backup and Recovery Manager
The following sections provide information about management of Backup and Recovery Manager.
NOTE: You cannot manage HP Backup and Recovery Manager using Microsoft Windows Management Instrumentation (WMI).
Enforcing policies/scheduling
The HP Backup and Recovery Manager provides a scheduling utility that after configured, requires no user intervention. HP recommends that the backup schedule be created immediately to ensure continued system and data security.
8 HP Backup and Recovery Manager Administrator Guide | ENWW |