QuickSpecs

HP Compaq dc7800 Business PC

Technical Specifications

Unit Environment and Operating Conditions

Ultra-slim Desktop

Small Form Factor

Convertible Minitower

General Unit Operating Guidelines

Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is operated within the specified operating range.

Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow. Never restrict airflow into the computer by blocking any vents or air intakes.

Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re- circulated or preheated air.

Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign matter can block the vents and limit the airflow.

If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the enclosure, and the same operating guidelines listed above will still apply.

Temperature Range

Operating: 50° to 95° F (10° to 35° C)*

 

Non-operating: -22° to 140° F(-30° to 60° C)

Relative Humidity

Operating: 10% to 90% (non-condensing at ambient)

 

Non-operating: 5% to 95% (non-condensing at ambient)

Maximum Altitude

Operating: 10,000 ft (3048 m)

(unpressurized)

Non-operating: 30,000 ft (9144 m)

*Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.

Power Supply

Ultra-slim Desktop

Small Form Factor

Convertible Minitower

Power Supply

135W external power supply, 85%

240W power supply, active PFC

365W power supply, active PFC

 

efficient, active PFC

 

 

Operating Voltage Range

90 – 264 VAC

90 – 264 VAC

90 – 264 VAC

Rated Voltage Range

100 – 240 VAC

100 – 240 VAC

100 – 240 VAC

Rated Line Frequency

50/60 Hz

50/60 Hz

50/60 Hz

Operating Line Frequency

47 – 63 Hz

47 – 63 Hz

47 – 63 Hz

Range

 

 

 

Rated Input Current

N/A

4A

6A

Rated Input Current with

1.5A

3.5A

5A

Energy Efficient* Power

 

 

 

Supply

 

 

 

Current Leakage

< 275 µA

< 275 µA

< 450 µA

(NFPA 99)

 

 

 

System Heat Dissipation

N/A

Typical 198 btu/hr

Typical 222 btu/hr

 

 

(50 kg-cal/hr)

(56 kg-cal/hr)

 

 

Maximum 1260 btu/hr

Maximum 1916 btu/hr

 

 

(318 kg-cal/hr

(483 kg-cal/hr)

System Heat Dissipation

Typical 133 btu/hr

Typical 150 btu/hr

Typical 171 btu/hr

with Energy Efficient* Power

(33.5 kg-cal/hr)

(38 kg-cal/hr)

(43 kg-cal/hr)

Supply

Maximum 549 btu/hr

Maximum 1024 btu/hr

Maximum 1557 btu/hr

 

(132 kg-cal/hr)

(258 kg-cal/hr)

(392 kg-cal/hr)

Power Supply Fan

N/A

80mm variable speed

92mm variable speed

DA - 12744 North America — Version 25 — May 16, 2008