QuickSpecs
HP ProLiant ML110 Generation 5 (G5)
Technical Specifications
System Unit | Dimensions (HxWxD) | 14.5 x 6.9 x 16.8 in (36.7 x 17.5 x 42.6 cm) | ||
|
| (with feet) |
|
|
|
| Weight (approximate) | Maximum | 39 lb (17.5 kg) |
|
|
| (all hard drives, power |
|
|
|
| supplies, and processors |
|
|
|
| installed) |
|
|
|
| Minimum | 23.81 lb (10.8 kg) |
|
|
| (one hard drive, power |
|
|
|
| supply, and processor |
|
|
|
| installed) |
|
|
| Input Requirements | Rated Line Voltage | 90 to 132 VAC, |
|
| (per power supply) |
| 180 to 264 VAC |
|
|
| Rated Input Current | 6 A (at 100 VAC), |
|
|
|
| 3 A (at 200 VAC) |
|
|
| Rated Input Frequency | 47 to 63 Hz |
|
|
| Rated Input Power | 600 W (at 100 VAC), |
|
|
|
| 600 W (at 200 VAC) |
|
| Power Specifications | To review typical system power ratings use the Power Calculator which is | |
|
|
| available via the online tool located at URL: | |
|
|
| ||
|
|
| ||
|
|
| - Click on the system of interest. Example: DL380 G5 | |
|
|
| - Follow the instructions of the next screens. | |
|
| Power Supply Output | Rated | 365 W (at 100 VAC), |
|
| (per power supply) |
| 365 W (at 200 VAC) |
|
|
| Maximum Peak Power | 385 W (at 100 VAC), |
|
|
|
| 385 W (at 200 VAC) |
|
| System Inlet Temperature | Operating | 10° to 35°C (50° to 95°F) at sea level with an |
|
|
|
| altitude derating of 1.0°C per every 305 m |
|
|
|
| (1.8°F per every 1000 ft) above sea level to a |
|
|
|
| maximum of 3050 m (10,000 ft), no direct |
|
|
|
| sustained sunlight. Maximum rate of change is |
|
|
|
| 10°C/hr (18°F/hr). The upper limit may be |
|
|
|
| limited by the type and number of options |
|
|
|
| installed. |
|
|
|
| System performance may be reduced if operating |
|
|
|
| with a fan fault or above 30°C (86°F). |
|
|
| ||
|
|
|
| change is 20°C/hr (36°F/hr). |
|
| Relative Humidity | Operating | 10% to 90% relative humidity (Rh), 28°C |
|
|
| (82.4°F) maximum wet bulb temperature, non- | |
|
|
|
| condensing. |
|
|
| 5% to 95% relative humidity (Rh), 38.7°C | |
|
|
|
| (101.7°F) maximum wet bulb temperature, non- |
|
|
|
| condensing. |
|
| Altitude | Operating | 3050 m (10,000 ft). This value may be limited by |
|
|
|
| the type and number of options installed. |
|
|
|
|
|
DA - 12867 North America — Version 14 — September 15, 2008 | Page 27 |