AC Controls

Contactors — Non-Reversing

General

 

 

 

 

 

 

 

 

NEMA Size 1

 

NEMA Size 3

 

NEMA Size 5

 

 

 

 

 

 

 

 

Type 3TF Non-Reversing AC Contactors

Key Features

JFully NEMA Rated Sizes 00–8

JDouble Break Contacts

JSilver Tin Oxide Contacts, Cadmium- Free (Sizes 00–5)

JHigher Locked Rotor Current Ratings, Up to 840% (Sizes 00–5)

JArc Chutes with Arc Splitters; Fast Arc

Quenching.

Table 15.27 Contactor Technical Data

JLowest Contact Bounce (2 Milliseconds or less on Most Sizes)

JTouch Safe Power Terminals (Sizes 00–3)

JTouch Safe Control Terminals (Sizes 00–5)

JSnap-on 2 NO and 2 NC Auxiliary Contacts Standard (Sizes 00–5)

JVisual ON / OFF indicator

JColor-Coded Coils

JFast Termination System — Wire Funnels, Wire Stops, Screwdriver Guide Holes, and Captive Hardware

JLong Mechanical Life

15 Million (Size 00)

10 Million (Size 0–5)

5 Million (Size 6–8)

JUL Listed and CSA Certified

15

AC Controls

 

 

 

 

NEMA Size

 

 

 

 

 

 

 

 

Measured Parameter

 

 

00

0

1

2

3

4

5

6

7

8

Ampere Rating (Open)

Amps

10

20

30

50

100

150

300

600

900

1350

Ampere Rating (Enclosed)

Amps

9

18

27

45

90

135

270

540

810

1215

Maximum Voltage Rating

Volts

600

600

600

600

600

600

600

600

600

600

Squirrel Cage

 

200 V, 60 Hz

 

1.5

3

7.5

10

25

40

75

150

Motor Maximum

 

230 V, 60 Hz

 

1.5

3

7.5

15

30

50

100

200

300

450

Horsepower

 

HP

 

380 V, 50 Hz

1.5

5

10

25

50

75

150

300

 

 

 

 

 

460–575 V, 60 Hz

 

2

5

10

25

50

100

200

400

600

900

Resistive

 

120 VAC

 

3

5

10

15

30

60

90

a

Heating

 

240 VAC

 

6

10

20

30

60

120

180

a

(1-Phase

 

kW

2-Pole)

 

480 VAC

 

12

20

40

60

120

240

360

a

 

 

600 VAC

 

15

25

50

75

150

300

450

a

Resistive

 

120 VAC

 

5

8.5

17

26

52

105

155

a

Heating

 

240 VAC

 

10

17

34

68

105

210

315

a

(3-Phase

 

kW

 

480 VAC

20

34

68

105

210

415

625

 

3-Pole)

 

 

a

 

 

600 VAC

 

25

43

86

130

260

515

775

a

Capacitor

 

240 VAC

 

12

27

40

80

160

240

360

Switching

 

 

 

 

 

 

 

 

 

 

 

 

 

 

480 VAC

KVAR

25

53

80

160

320

480

720

(3-Phase)

 

 

600 VAC

 

31

67

100

200

400

600

900

 

 

 

Transformer

 

120 VAC

 

0.6

1.2

2.1

4.1

6.8

14

27

41

61

Switching

 

240 VAC

 

1.2

2.4

4.1

8.1

14

27

54

81

122

(1-Phase

 

kVA

 

480 VAC

2.4

4.9

8.3

16

27

54

108

162

244

2-Pole)

 

 

 

 

600 VAC

 

3

6.2

10

20

34

68

135

203

304

Transformer

 

208 VAC

 

1.8

3.6

6.3

12

30

41

81

122

182

Switching

 

240 VAC

 

2.1

4.3

7.2

14

23

47

94

140

210

(3-Phase

 

kVA

 

480 VAC

4.2

8.5

14

28

47

94

188

280

420

3-Pole)

 

 

 

 

600 VAC

 

5.2

11

18

35

59

117

1350

351

525

AC Coil

 

Overall

Hz

50/60

50/60

50/60

50/60

50/60

50/60

50/60

60

60

60

Ratings

 

Inrush

VA

68/87

101/32

101/32

183/233

330/410

910/1090

2450/2960

2900

4000

4200

 

 

 

 

Sealed

VA

10/12

12.1/16.1

12.1/16.1

17/21

32/39

58/70

115/146

105

140

100

Operating

 

to 10% overvoltage,

 

 

 

 

 

 

 

 

 

 

 

Times

 

(warm or cold coil) Total

MS

10–35

13–67

13–67

15–40

20–50

20–50

17–65

30–50

30–50

40–80

(valid for 20%

 

Opening Time Includes

 

 

 

 

 

 

 

 

 

 

 

 

Undervoltage)

 

Arcing Time Closing Delay

 

 

 

 

 

 

 

 

 

 

 

Operating

 

 

15–30

15–20

15–20

15–35

15–35

20–40

18–30

10–20

10–20

140–240

Resistance To Shock (Rectangular pulse)

G/MS

5.5/5 3.2/10

5.7/5 9/5

5.7/5 9/5

9.2/5 4.8/10

8.6/5 4.8/10

10.4/5 5.8/10

8.8/5 4.9/10

Conductor size/phase

AWG

(2) 14–10

(2) 14–3

10–1/0

10–1/0

10–1/0

2-300MCM

1-500MCM

(2) 4–500

(3) 2–600MCM

(4) 2/0–500MC

Auxiliary Contact Wire Size

AWG

(2) 18–12

(2) 18–12

(2) 18–12

(2) 18–12

(2) 18–12

(2) 18–12

(2) 18–12

(2) 18–12

(2) 18–12

(2) 18–12

Mechanical Life (make/break operations)

MILL

15

10

10

10

10

10

10

5

5

5

Total Auxiliary Contacts Available

 

4

4

4

8

8

8

8

8

8

8

Auxiliary Contact Rating A600/P600

 

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

aFor ratings contact Siemens.

298

Siemens Electrical Products and Systems

CSI Section 16160

Specification Guide