WARRANTY

This product is warranted against detects in materials and workmanship for one year following the date of purchase by the original owner. This warranty does not include damage to the product as a result of misuse, accident, damage, modifications or alterations, and it does not apply if the instructions in this manual are not followed.

RECOMMENDED ACCESSORIES

FOR THE OS-3

If a defect develops during the warranty period, Eco, Sensors at its election will repair the instrument or will replace it with a new or reconditioned model of equivalent quality. In the event of replacement with a new or reconditioned model, the replacement unit will continue the warranty of the original unit.

If the product should become defective during the warranty period, it should be returned freight prepaid with proof and date of purchase to the address indicated by calling (800) 472-6626,r faxing (505) 988-1315 or e-mailing to sales@ecosensors.com

Except as provided herein, Eco Sensors makes no warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. Eco Sensors shall not be liable for loss or use of this instrument or other incidental or consequential damages, expenses or economic loss, or claims for such damage or economic loss.

This warranty gives you specific rights, and you may also have other rights which vary from state to state.

RECORD YOUR SERIAL NUMBER HERE_______________________________KEEP THIS MANUAL FOR YOUR RECORDS

Eco Sensors is a registered trademark of Eco Sensors, Inc.

Ozone Switch is a trademark of Eco Sensors, Inc.

(c) Eco Sensors, Inc., 2000. Revision 1. For OS-3 REV. 1.

OG-1 Ozone Test Generator Hand-held. Generates up to about 7 ppm for verifying instrument response.

OG-2 Ozone Source Calibrator Precision UV lamp calibrated ozone source. Generates .1 ppm reference concentration. Battery operated. Small and simple to use.

DL Series Data Loggers Tiny battery- operated data loggers record data for later analysis in PCs.

Relay Contacts 5A 250 V.Max.
50 Set-Point Adjustment

 

 

ScalePPM

K1

 

Do Not Use Below 5 (.5 PPM)

0

10

1

 

 

50

5

 

SET POINT

100

10

0-10 PPM
Data Logger

TB2TB1

N.C.

COM.

N.0.

1V-0

OUTPUT
GND
24VDCIN
Power in if Jack
is not used

 

 

 

 

 

 

 

 

 

 

 

 

 

12-

 

 

 

+5V

GNDSENSOR

 

 

 

Sensor Module

TB3

J1

Cable Connection

 

 

 

 

 

Power Jack

CAUTION! Avoid excessive touching of the inlet end of the sensor and keep it free from chemicals, lubricants, dust, water, etc. Do not use silicone caulking compound or RTV near the sensor