Installation

PUMP INSTALLATION

IMPORTANT: Pump is built to handle clear water only; it is not designed to handle water containing sand, silt or other abrasives.

1.Refer to Figures 6, 7, and 8 for typical installations.

Support pump and piping when assembling and when installed. Failure to do so may cause piping to break, pump to fail, motor bearing failures, etc.

2.If the pump is used as part of a per- manent installation, bolt to a rigid foundation.

!

Use only compo-

nents that are rated for maximum pressure pump can produce when used in boosting system or any other system. Do not exceed the total maximum pressure boost as listed per model in Performance Charts B.

PRESSURE BOOST SYSTEMS

1.On pressure boost systems, locate the pump so that there will always be a positive supply of water to the pump (See Figures 6, 7 and 8).

2.For service convenience, install a gate valve and union in the inlet and discharge line.

Do not use a globe valve or other restricting type of valve that will seriously restrict the pumps discharge capacity.

No Sags

Sags Allow Air Pockets

No Air Leaks In

Pipe Joint Compound

Inlet Pipe

Will Damage Plastic

 

 

 

 

If Air Flows

 

 

 

Water

 

 

 

Won’t

 

 

 

 

IL0419

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If Air Pockets Form,

 

 

 

IL0418

 

 

 

 

 

IL0420

 

Water Won’t Flow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use Teflon Tape

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2 - No Air Pockets in Inlet Pipe

 

Figure 3 - Inlet Pipe Must Not Leak

Mount pump in correct position or pump failure will result.

Correct

 

Incorrect

IL0315

 

Figure 4A

 

Figure 4B

 

 

 

 

 

 

SAND AND SEDIMENT TRAP FILTER

3.Install a check valve as shown in Figure 6. Be sure check valve flow arrows point in the direction of water flow.

4.Whenever dirt, sand or debris is present in the supply water, install a strainer or filter on the inlet side of the pump (See Figure 7).

NOTE: For heavy amounts of sedi- ment, install a trap filter on the inlet

Standard Pressure

Tank - 42 Gallon Or

Larger

Inlet

Outlet

side of the pump (See Figure 5). NOTE: Pressure gauges installed before and after the filter will show

Sand Settles To The Bottom

Clean Out

pressure differential indicating the

Figure 5

IL0421

need for filter replacement or clean- ing.

IMPORTANT: Clean all filters and strainers on a regular schedule.

5

FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com