Installation
PUMP INSTALLATION
IMPORTANT: Pump is built to handle clear water only; it is not designed to handle water containing sand, silt or other abrasives.
1.Refer to Figures 6, 7, and 8 for typical installations.
Support pump and piping when assembling and when installed. Failure to do so may cause piping to break, pump to fail, motor bearing failures, etc.
2.If the pump is used as part of a per- manent installation, bolt to a rigid foundation.
!
Use only compo-
nents that are rated for maximum pressure pump can produce when used in boosting system or any other system. Do not exceed the total maximum pressure boost as listed per model in Performance Charts B.
PRESSURE BOOST SYSTEMS
1.On pressure boost systems, locate the pump so that there will always be a positive supply of water to the pump (See Figures 6, 7 and 8).
2.For service convenience, install a gate valve and union in the inlet and discharge line.
Do not use a globe valve or other restricting type of valve that will seriously restrict the pumps discharge capacity.
No Sags | Sags Allow Air Pockets | No Air Leaks In | Pipe Joint Compound | |
Inlet Pipe | Will Damage Plastic | |||
|
| |||
|
| If Air Flows |
| |
|
| Water |
| |
|
| Won’t |
| |
|
|
| IL0419 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
If Air Pockets Form, |
|
|
| IL0418 |
|
|
|
|
| IL0420 | |
| |||||||||||
Water Won’t Flow |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| Use Teflon Tape |
| ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
Figure 2 - No Air Pockets in Inlet Pipe |
| Figure 3 - Inlet Pipe Must Not Leak |
Mount pump in correct position or pump failure will result.
Correct |
| Incorrect |
IL0315
| Figure 4A |
| Figure 4B |
|
|
|
|
|
|
SAND AND SEDIMENT TRAP FILTER
3.Install a check valve as shown in Figure 6. Be sure check valve flow arrows point in the direction of water flow.
4.Whenever dirt, sand or debris is present in the supply water, install a strainer or filter on the inlet side of the pump (See Figure 7).
NOTE: For heavy amounts of sedi- ment, install a trap filter on the inlet
Standard Pressure
Tank - 42 Gallon Or
Larger
Inlet
Outlet
side of the pump (See Figure 5). NOTE: Pressure gauges installed before and after the filter will show
Sand Settles To The Bottom
Clean Out
pressure differential indicating the
Figure 5
IL0421
need for filter replacement or clean- ing.
IMPORTANT: Clean all filters and strainers on a regular schedule.
5