Table 38 AUTO_SVOLPSUE

Local State

Remote State

Fence Level

AUTO_SVOLPSUE

AUTO_SVOLPSUE =1

 

 

 

=0 (Default)

or FORCEFLAG=yes

 

 

 

 

 

SVOL_PSUE

PVOL_PSUS

NEVER/DATA/ASYNC

Do not start with

Perform a SVOL to

SVOL_PSUE

EX_ENORMT

 

exit 2.

PSUS(SSWS). After

 

 

the takeover

SVOL_PSUE

EX_CMDIOE

 

 

 

 

succeeds, package

starts with a warning message about non-current data in the package’s control log file.

Table 39 AUTO_SVOLPSUS

Local State

Remote State

Fence Level

AUTO_SVOLPSUS =0 (Default)

AUTO_SVOLPSUS =1 or

 

 

 

 

FORCEFLAG=yes

 

 

 

 

 

SVOL_PSUS

PVOL_PSUS

NEVER/

Do not start with exit 2.

Perform a SVOL to PSUS

SVOL_PSUS

EX_ENORMT

DATA/

 

(SSWS). After the takeover

 

succeeds, package starts with

SVOL_PSUS

EX_CMDIOE

ASYNC

 

 

a warning message about

 

 

 

 

non-current data in the

 

 

 

 

package’s control log file.

 

 

 

 

 

 

 

 

 

 

NOTE: Environment File Variables for Device Group Monitor: Device Group Monitor is supported only with packages configured for two data centers (2DC).

The following list the monitor specific variables that have been modified or added for Metrocluster with Continuous Access for P9000 and XP. If a monitor variable is not defined (commented out), the default value is used:

MON_POLL_INTERVAL

(Default = 10 minutes)

 

This parameter defines the polling interval for the monitor

 

service (if configured). If the parameter is not defined

 

(commented out), the default value is 10 minutes. Otherwise,

 

the value will be set to the desired polling interval in minutes.

MON_NOTIFICATION_FREQUENCY

(Default = 0)

 

This parameter controls the frequency of notification

 

messages sent when the state of the device group remains

 

the same. If the value is set to 0, then the monitor will only

 

send notifications when the device group state changes. If

 

the value is set to n where n is greater than 0, the monitor

 

will send a notification every nth polling interval or when

 

the device group state has changed. If the parameter is not

 

defined (commented out), the default value is 0.

MON_NOTIFICATION_EMAIL

(Default = empty string)

 

This parameter defines the email addresses that the monitor

 

will use to send email notifications. The variable must use

 

fully qualified email addresses. If multiple email addresses

 

are defined, the comma must be used as a separator. If the

 

parameter is not defined (commented out) or the default

 

value is an empty string, this will indicate to the monitor that

 

no email notifications will be sent.

MON_NOTIFICATION_SYSLOG

(Default = 0)

 

his parameter defines whether the monitor will send

 

notifications to the syslog file. When the parameter is set to

 

0, the monitor will NOT send notifications to the syslog file.

484 Environment File Variables for Serviceguard Integration with Continuous Access P9000 or XP