
Table 38 AUTO_SVOLPSUE
Local State | Remote State | Fence Level | AUTO_SVOLPSUE | AUTO_SVOLPSUE =1 |
|
|
| =0 (Default) | or FORCEFLAG=yes |
|
|
|
|
|
SVOL_PSUE | PVOL_PSUS | NEVER/DATA/ASYNC | Do not start with | Perform a SVOL to |
SVOL_PSUE | EX_ENORMT |
| exit 2. | PSUS(SSWS). After |
|
| the takeover | ||
SVOL_PSUE | EX_CMDIOE |
|
| |
|
| succeeds, package |
starts with a warning message about
Table 39 AUTO_SVOLPSUS
Local State | Remote State | Fence Level | AUTO_SVOLPSUS =0 (Default) | AUTO_SVOLPSUS =1 or |
|
|
|
| FORCEFLAG=yes |
|
|
|
|
|
SVOL_PSUS | PVOL_PSUS | NEVER/ | Do not start with exit 2. | Perform a SVOL to PSUS |
SVOL_PSUS | EX_ENORMT | DATA/ |
| (SSWS). After the takeover |
| succeeds, package starts with | |||
SVOL_PSUS | EX_CMDIOE | ASYNC |
| |
| a warning message about | |||
|
|
|
| |
|
|
|
| package’s control log file. |
|
|
|
|
|
|
|
|
|
|
NOTE: Environment File Variables for Device Group Monitor: Device Group Monitor is supported only with packages configured for two data centers (2DC).
The following list the monitor specific variables that have been modified or added for Metrocluster with Continuous Access for P9000 and XP. If a monitor variable is not defined (commented out), the default value is used:
MON_POLL_INTERVAL | (Default = 10 minutes) |
| This parameter defines the polling interval for the monitor |
| service (if configured). If the parameter is not defined |
| (commented out), the default value is 10 minutes. Otherwise, |
| the value will be set to the desired polling interval in minutes. |
MON_NOTIFICATION_FREQUENCY | (Default = 0) |
| This parameter controls the frequency of notification |
| messages sent when the state of the device group remains |
| the same. If the value is set to 0, then the monitor will only |
| send notifications when the device group state changes. If |
| the value is set to n where n is greater than 0, the monitor |
| will send a notification every nth polling interval or when |
| the device group state has changed. If the parameter is not |
| defined (commented out), the default value is 0. |
MON_NOTIFICATION_EMAIL | (Default = empty string) |
| This parameter defines the email addresses that the monitor |
| will use to send email notifications. The variable must use |
| fully qualified email addresses. If multiple email addresses |
| are defined, the comma must be used as a separator. If the |
| parameter is not defined (commented out) or the default |
| value is an empty string, this will indicate to the monitor that |
| no email notifications will be sent. |
MON_NOTIFICATION_SYSLOG | (Default = 0) |
| his parameter defines whether the monitor will send |
| notifications to the syslog file. When the parameter is set to |
| 0, the monitor will NOT send notifications to the syslog file. |
484 Environment File Variables for Serviceguard Integration with Continuous Access P9000 or XP