QuickSpecs

HP Smart Array P410 Controller

Standard Features

Availability

Provides increased server uptime by providing advanced storage functionality:

Online RAID level migration (between any RAID level/with BBWC/FBWC )

Online stripe size migration

Online array expansion

Online logical drive extension

Online drive firmware upgrade

Unlimited global online spare

Pre-Failure Warranty

Fault Prevention

The following features offer detection of possible failures before they occur, allowing preventive action to

 

be taken:

 

S.M.A.R.T.: Self Monitoring Analysis and Reporting Technology first developed at HP detects

 

possible hard disk failure before it occurs, allowing replacement of the hard drive before a real

 

failure occurs.

 

Drive Parameter Tracking monitors drive operational parameters, predicting failure and notifying

 

the administrator.

 

Dynamic Sector Repairing continually performs background surface scans on the hard disk drives

 

during inactive periods and automatically remaps bad sectors, ensuring data integrity.

 

Smart Array Cache Tracking monitors integrity of controller cache, allowing pre-failure preventative

 

maintenance.

 

 

Fault Tolerance

Keeps data available and server running while a failed drive is being replaced; several fault tolerance

 

configurations are supported including:

 

RAID 6 with ADG (Advanced Data Guarding): This is the highest level of fault tolerance. It allocates

 

two sets of parity data across drives and allows simultaneous write operations. This level of fault

 

tolerance can withstand two simultaneous drive failures without downtime or data loss.

 

RAID 6+0: Supported with min of 8 drives, but would have 4 available. Target benefit is to split RAID

 

across the external boxes

 

NOTE: RAID 6, 6+0 can be enabled with either

 

Minimum of 256 MB cache with Battery and Smart Array Advanced Pack License key option

 

upgrades

 

Minimum of 512 MB BBWC/FBWC and Smart Array Advanced Pack License key option

 

upgrades

 

RAID 5 (Distributed Data Guarding): This allocates one set of parity data across drives and allows

 

simultaneous write operations. This level of fault tolerance can withstand a single drive failure

 

without downtime or data loss.

 

RAID5 is available on the SA P410/P410i with a minimum of 256MB cache and battery

 

RAID 5+0: This is a RAID 0 array striped across 5 elements. Combines the straight block-level

 

striping of RAID 0 with the distributed parity of RAID 5.

 

RAID 1, 1+0 (Drive Mirroring): This allocates half of the drive array to data and the other half to

 

mirrored data, providing two copies of every file. It is a high-performance RAID.

 

 