c. Reboot the system.

4.Update the firmware on each device to the latest version using the fio-update-iodriveTSM or COS command-line utility.

CAUTION: Do not turn off the power during a firmware upgrade, because this might cause device failure. If a UPS is not in place, consider adding one to the system before performing a firmware upgrade.

Sample syntax:

fio-update-iodrive <iodrive_version.fff>

Where <iodrive_version.fff> is the path to the firmware archive. This command updates all of the devices to the selected firmware. If you wish to update specific devices, consult the utility reference for more options.

5.Reboot the system.

If the fio-statuscommand is run, a warning that the upgraded devices are missing a lebmap appears. This warning is customary, and the issue will be corrected in the next step.

CAUTION: Running the fio-formatcommand in the next step erases the entire device, including user data. After this format is started, the device cannot be downgraded to the 2.x driver without voiding your warranty.

6.Format each device using the fio-formatcommand. For example: fio-format <device>

You are prompted to confirm you want to erase all data on the device. The format might take an extended period of time, depending on the amount of wear on the device.

7.Using the following command, attach all IO Accelerator devices: fio-attach /dev/fct*

8.Using the following command, check the status of all devices: fio-status-a

Your IO Accelerator devices are now successfully upgraded for this version of the HP IO Accelerator. You can now install any IO Accelerator Gen2 devices.

Enabling PCIe power

For PCIe IO Accelerators, if you have installed any dual IO Accelerator devices, such as the HP ioDrive2 Duo, then the device might require additional power than the minimum 25 W provided by PCIe Gen2 slots to properly function.

For instructions on enabling the device to draw additional power from the PCIe slots, see "Enabling PCIe power override (on page 23)."

Configuring the device to support VM disks

Software installation 19