Hubbell 31.210 manual Outline Drawings, Specifcations, Hubbell Industrial, Controls, Inc

Models: 31.210

1 2
Download 2 pages 35.03 Kb
Page 2
Image 2
Outline Drawings

Outline Drawings

Specifcations

25.50

Alternate Mtg Position

24.00

8.00

22.50

 

22.50

24.00

25.50

Cast Hinges With Removable Hinge Pins

Shown With Door Removed

Receiver Cabinet

Weight — 90 lbs.

Pneumatic Cabinet

Weight — 110 lbs.

24.00

22.50

25.50

24.00

C

 

 

L

Supply Voltage

12VDC, 24VDC, 36VDC or 72VDC

Internal Power Requirements

+11.9–13.1VDC & +4.5–6.5VDC, 24 VDC

Operating Temperature

–22°F (–30°C) to 140°F (+60°C)

Radio Receiver

4.13

Frequency Range

72–76 MHz or 450–470 MHz

 

 

Channel Availability

as required by user

 

Frequency Stability

±5 ppm

24.00

Sensitivity

1 µv @ 20 dB quieting

 

Data Reception

compatible with Hubbell transmitters

 

Modulation

Manchester II (bi-phase)

 

Baud Rate

4800 bps

 

Message Format

preamble, sync, start flag, address, control, CRC

 

 

check code

Control Section

Single board computer consisting of 80C31 controller, 64k EPROM,
EPLD containing circuits for bi-phase decoding

DC Output Section (Electro-mechanical relays)

Panel mounted mother-board to accommodate 4 plug-in relay boards, each with 6 output relays, for a maximum of 24 ac output relays and 12 sense inputs

Indicators

LED on each output

Feedback Sensing

opto-isolated input from: AIR PRESSURE,

 

THROTTLE, BRAKE, FORWARD, REVERSE

 

relay outputs

Relays

Standard PC board relays

Output Rating

115/230V ac, 50/60 Hz, 5A resistive;

 

12/24V dc, 5A resistive

Isolation

5000V

DC Output Section (Stepped analog outputs)

Panel mounted mother-board to accommodate 4 plug-in boards, each with 1 analog output.

12.00

Right Side View Of Cabinet W/door Closed

Indicators

LED on each of 8 levels

Output Rating

0–10V dc, 20mA, in 8 steps

Isolation

5000V

“E-Stop” Board

Plug-in PC board (plugs into motherboard of DC Output Section in place of 1 electro- mechanical relay board)

F12 F13 F14 F15

F7 F8 F9 F10 F11

F1 F2 F3 F4 F5 F6

Indicators

LED on each of 5 inputs and 1 output

Inputs

5 inputs, optically isolated

Isolation

5000V

Control Relays (DIN Rail Mounted)

Individual control relays, as required for locomotive functions.

HUBBELL

50 Edwards Street

NEMA P300 DC Inductive Rating

5A Continuous at 250VDC Max.

Madison, Ohio 44057

 

138VA Make & Break Max.

(440) 428-1161

 

 

Fax (440) 428-7635

 

 

Hubbell Industrial

Controls, Inc.

4301 Cheyenne Drive

a subsidiary of

Archdale, NC 27263

(336) 434-2800

Hubbell Incorporated

Fax (336) 434-2801

JPS-100-1M © 2000

Hub ell Industrial Control Solutions

 

http://www.hubbell-icd.com/radiocontrols/

Printed in U.S.A.

Page 2
Image 2
Hubbell 31.210 Outline Drawings, Specifcations, Hubbell Industrial, Controls, Inc, Radio Receiver, Control Section