CABLE INSTALLATION & REMOVAL

Use the procedure detailed on HAZARDOUS DUTY CABLE REEL SEALING INSTRUCTIONS (bulletin 039789) which comes with sealing kit (available separately).

CAUTION

Carefuly read and follow instructions

supplied with separate sealing kit as well as instructions for sealing compound. Failure to properly follow those instructions could result in damage to equipment, personal injury or death.

CABLE REMOVAL

CAUTION

Always open all breakers and disconnect electrical power to reel. Failure to turn off electrical power could lead to serious injury or death.

1.Move machine serviced by reel to a position closest to reel. Springs will still be under pre-tension at this point.

2.Turn off all power to reel.

3.Remove collector cover and gasket.

4.Disconnect electric leads to and from collector.

5.Follow Steps 3–9, REMOVING OLD CABLE,

on bulletin 039789.

CABLE INSTALLATION REFERENCE DRAWING

 

 

COLLECTOR

COLLECTOR

 

U-BOLT

 

 

ENTRANCE

 

 

 

COVER

 

 

 

 

 

 

SPOOL

LOCKING

COLLECTOR

COLLECTOR

SPRING

COLLAR

ENCLOSURE

SHAFT

 

 

 

COLLECTOR

HOUSING

 

 

 

 

 

 

 

 

ENCLOSURE

 

 

 

 

 

 

 

 

 

 

ASSEMBLY

 

 

 

 

 

Shown in Fig 2

 

 

 

 

 

without cover.

 

 

 

 

 

CONDULET

 

 

 

 

 

NIPPLE

 

 

 

 

COLLECTOR

NOTE: This is FACTORY

 

 

 

 

SEALED. Check seal

 

 

 

 

 

SPOOL SHAFT

DRIVE

 

DRIVE

INSTALLED CABLE

integrity when

 

installing new cable.

WATER TIGHT

STOP BOLT

BRACKET

 

 

 

 

 

 

 

 

 

 

 

CONNECTOR

 

 

 

 

 

HUBBELL

 

GLEASON REEL CORP.

®

P.O. Box 26 • 600 South Clark St.

 

Mayville, WI 53050–0026

®

Phone 920–387–4120 • Fax 920–387–4189

A Hubbell Company

 

Printed in USA

Bulletin No. 044625.a

Page 4
Image 4
Hubbell SZ-32 manual Cable Installation & Removal, Cable Removal, Cable Installation Reference Drawing, Gleason Reel Corp