Hubbell Electric Heater Company D Annual Inspection, b.Close valve on hot water outlet piping

Models: D

1 24
Download 24 pages 17.12 Kb
Page 13
Image 13

ANNUAL INSPECTION

1.Flush tank as follows

a.Shut off power supply.

b.Close valve on hot water outlet piping.

c.Open valve on drain piping.

d.Cold water inlet line pressure will be strong enough to flush sediment from the bottom of the tank out through the drain. Let water run for 3-4 minutes.

e.Close drain valve.

f.Open hot water valve.

g.Turn power supply ON.

13

Page 13
Image 13
Hubbell Electric Heater Company D Annual Inspection, Flush tank as follows a.Shut off power supply, g.Turn power supply ON