7. Carefully remove the Lamp from the unit. Refer to Fig. 14.

Fig. 14

8.Carefully insert the new UVC Lamp’s copper prongs into the Lamp Sockets, and twist the

Lamp until it is securely in place.

9.Position the Lamp Cover over the Lamp, and slide it downward until it is sceurely in place.

NOTE: THE UNIT WILL NOT OPERATE IF THE LAMP COVER IS NOT INSTALLED

CORRECTLY.

10.Install the Lamp Cover Screws.

11.Press the filter firmly into the Air Purifier. To avoid damaging the filter media, you should press on the frame of the filter only. Refer to page 12. NOTE: THIS UNIT WILL NOT

OPERATE UNLESS FILTER IS INSTALLED CORRECTLY AND SEATED PROPERLY.

12.Place the Front Grill back onto the unit. First, line up the tab on the bottom of the Grill with the recess on the purifier base and then push the top of the Grill forward until it is closed. Refer to Figs. 6 and 7, pg. 7. NOTE: THIS UNIT WILL NOT OPERATE UNLESS THE FRONT GRILL IS INSTALLED CORRECTLY.

13.Plug in the unit and turn it on. If the unit does not operate, check the installation of the Lamp Cover and the Front Grill.