Hunter Fan 35180 warranty warnings, using your vaporizer, cleaning and care, troubleshooting

Models: 35180

1 2
Download 2 pages 10.32 Kb
Page 2
Image 2
warnings
Medicine Cup
Figure E
Figure D
Figure F

warnings

READ AND SAVE THESE INSTRUCTIONS

This vaporizer may not work properly on an uneven surface. ALWAYS place this vaporizer on a firm, level, and water resistant surface. ALWAYS place the vaporizer at least six (6) inches away from walls and heat sources such as stoves, radiators, or heaters.

ALWAYS place the vaporizer in an area that is out of the reach of children. Supervision is recommended when the vaporizer is used near children, invalids or pets.

Before using the vaporizer, extend the cord and inspect for any signs of damage. DO NOT use the product if the cord has been damaged.

This product has a polarized plug (one blade is wider than the other) as a safety feature. This plug will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat or override this safety feature.

ALWAYS UNPLUG and empty the vaporizer when it is not in operation or while it is being emptied, filled or cleaned.

DO NOT tilt or move the vaporizer while it is in operation.

DO NOT direct steam towards people, the wall or furniture. Do not place the vaporizer under a tent.

DO NOT touch the unit or steam vapors during use. Steam is hot and burns can occur.

DO NOT add medication of any type into the water in the container. Do not cover the steam outlet or place anything over it while the vaporizer

is operating. Never drop or insert any object into any opening.

using your vaporizer

1.

Remove the plastic covering from the vaporizer. Remove

 

 

the tape from the water level indicator.

 

2.

Unravel and straighten out the cord before use.

 

 

Always unplug the cord from the electrical outlet and

 

 

the steam unit before removing the steam unit or when

Figure A

 

not in use. Allow vaporizer to cool before handling.

 

 

 

3.Remove the steam unit from the ToteAwayTM tank. Twist the steam unit counterclockwise and lift it out of the ToteAwayTM tank. Refer to Figure A & B.

4.Fill the ToteAwayTM tank with tap water. Fill the con- tainer until the water level indicator shows the MAX marking. Refer to Figure C. DO NOT OVERFILL.

5.Add salt. For tap water of low or moderate mineral con-

tent, add 4 to 5 pinches (1/8 teaspoon) of ordinary table

 

 

Steam Unit

 

 

 

salt to the water and mix thoroughly. Salt has no effect

 

 

 

on the purity of the steam or medication.

 

 

 

If an adequate steam flow is not obtained after ten min-

 

 

 

utes, add another pinch or two as needed and mix thor-

 

 

 

oughly.

 

Figure B

 

If you live in a “hard-water” area, the vaporizer may op-

 

 

 

 

 

 

erate well without salt additive.

 

 

 

 

CAUTION: Too much salt can cause excessive boiling or a

 

 

 

 

 

 

blown fuse.

 

 

 

 

 

6.

Replace the steam unit. Align the arrows as shown and twist clock-

 

 

 

Water Level

 

 

wise to lock back in place. Refer to Figure A & B.

 

 

 

Indicator

 

7.

Place the vaporizer in a safe position. Vaporizer should always be

 

 

 

 

 

 

 

 

 

 

 

placed on a firm, flat surface at least four feet away from the bed-

 

 

 

 

 

 

side and out of the reach of the patient and children. Be sure the

 

 

 

 

 

 

vaporizer is in a stable position and the power cord is out of the

 

 

 

 

 

 

way to prevent the vaporizer from being upset or tipped over.

 

Figure C

 

 

 

NOTE: Protect the floor, rug or furniture by placing the vaporizer

 

 

 

 

 

 

 

 

 

 

 

 

on a non-metallic, waterproof, heat-resistant surface.

 

 

 

 

 

 

CAUTION: Do not direct steam flow directly at patient, walls

 

 

 

 

 

 

or furniture. You will still obtain the desired level of humidity.

 

 

 

 

 

 

Keep out of the reach of children. Steam can cause burns.

 

 

 

 

 

8.When using vaporizer medications, fill the medicine cup on the steam unit as directed by the instructions on the medicine pack- age. Refer to Figure E.

CAUTION: Do not add medication of any type into the water in the ToteAwayTM tank .

9. Plug in the unit. Firmly insert the plug in the steam unit. The 2-in- 1TM Easy LockTM feature prevents you from inserting the plug into

the steam unit until the steam unit is locked in place. Refer to Figure D.

Plug the power cord into 110-120 Volts AC outlet in good condition fused for at least 15 Amps. DO NOT use with extension cords.

CAUTION: This product has a polarized plug (one blade is wider than the other) as a safety feature. This plug will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat or override this safety feature.

Use the Vari-MistTMselector to control the amount of vapors released.

Vaporizer will produce a gentle flow of steam within a few minutes. If steaming does not start within ten minutes, you may need to add salt. Please see the troubleshooting section. The vaporizer will automatically stop producing steam when the water has reached the minimum level which will be indicated when the water level indicator is showing MIN. Refer to Figure C. The NiteGloTM power light will remain on indicating that the vaporizer is still plugged in. ALWAYS unplug the steam unit and allow to cool before removing the ToteAwayTM tank.

10.Use fresh water and medication each time the vaporizer is used.

11.After each use, open the Easy Drain plug and empty any unused water from the ToteAwayTM tank. Refer to Figure F. Shake the

ToteAwayTM tank gently back and forth to remove any remaining water. Rinse the ToteAwayTM tank thoroughly, drain and wipe with a dry, clean cloth.

All medicinal ingredients should be released in use, leaving only the mineral oil base in the removable medicine cup. The medicine cup may be removed and cleaned. Refer to Figure E.

Both the ToteAwayTM tank and the removable medicine cup are dishwasher safe.

IMPORTANT: To maintain proper operation of your vaporizer, be sure to follow the cleaning and care instructions.

cleaning and care

ALWAYS disconnect the plug from the electrical outlet and the plug from the steam unit and allow the unit to cool before cleaning. Remove the steam unit, letting all water drain back into the ToteAwayTM tank.

The 2-in-1TMEasy LockTM feature prevents you from removing the steam unit until the plug is removed from the steam unit.

DO NOT attempt to disassemble the steam unit.

daily maintenance

Open the Easy Drain plug and empty any unused water from the ToteAwayTM tank. Refer to Figure F. Rinse the ToteAwayTM tank thor- oughly with water, drain and wipe with a dry, clean cloth. Remove and clean the removable medicine cup.

Both the ToteAwayTM tank and the removable medicine cup are dishwasher safe.

weekly maintenance

1.Open the Easy Drain plug and empty unused water from the ToteAwayTM tank. Refer to Figure F.

2.Create a 50/50 solution of vinegar and water which should be 1/2 gallon vinegar and 1/2 gallon water. Pour this solution into the ToteAwayTM tank. Be sure to only fill the tank to the MAX line as indicated on the water level indicator. Refer to Figure C.

3.With the steam unit safely unplugged, place the steam unit back into the ToteAwayTM tank and soak for 30 minutes. After soaking for 30 minutes, remove the steam unit.

4.Empty the solution from the tank and rinse the tank. Fill the tank with tap water to the MAX line as indicated on the water level indicator. Refer to Figure C. Place the steam unit back into the tank for 30 seconds. Remove the steam unit and empty the water. Repeat the rinsing steps until the vinegar smell is gone.

5.The ToteAwayTM tank has built-in antimicrobial properties to inhibit the growth of bacteria, mold and fungi that may affect the tank. To clean, empty the tank and rinse with tap water until the vinegar smell is gone. Dry with a clean cloth. Remove and clean the removable medicine cup.

Both the ToteAwayTM tank and the removable medicine cup are dishwasher safe.

end-of-season maintenance

Follow the weekly maintenance procedure at end-of-season or when the vaporizer will not be used for several days. Be sure to dry all parts and store in a cool, dry location. Do not store unit with water inside.

troubleshooting

A.Vaporizer does not operate or steams too slowly:

1.Make sure the vaporizer is plugged in and the NiteGloTM power light is on.

If the NiteGloTM power light is not on, you may have a blown fuse, tripped circuit breaker or a defective electrical outlet. Try a different outlet. You may want to contact an electrician to check the potentially defective outlet.

2.The fault may be the low mineral content of the water in your area.

Unplug the vaporizer from the electrical outlet and allow to cool. Remove the steam unit al- lowing hot water to first dribble out, then add one or two pinches of salt to the water and mix thoroughly. Replace the steam unit and plug in the vaporizer. It should steam within 5 minutes.

Page 2
Image 2
Hunter Fan 35180 warnings, using your vaporizer, cleaning and care, troubleshooting, daily maintenance, weekly maintenance