Hunter Fan 40352, 40351 manual Line Voltage Thermostat Manual, Removal and Installation

Models: 40352 40351

1 2
Download 2 pages 15.62 Kb
Page 1
Image 1
®LINE VOLTAGE THERMOSTAT MANUAL

®LINE VOLTAGE THERMOSTAT MANUAL

Welcome to the Hunter Home Comfort family of quality products. The line voltage thermostats are designed for operation with resistance heating elements and unit heaters. These thermostats use snap action switches and do not require leveling. There are two models: 40351–single pole and 40352–double pole.

Removal and Installation:

WARNING: HIGH VOLTAGE – RISK OF ELECTRICAL SHOCK. Before removing the existing thermostat and installing your Hunter thermostat, disconnect the power to the furnace to avoid an electrical hazard.

1)Before disconnecting your existing thermostat, make sure that you note and label how the wires were connected to the thermostat. 2) Remove the existing thermostat.

3)Your Hunter thermostat is made up of three sections: the baseplate, the cover, and the knob. 4) Connect the wires from the wall to the baseplate screw terminals according to the connection diagrams for each model. Connect the ground wire to the ground screw on the baseplate.

Caution: Failure to connect the ground wire could result in electrical shock. 5) Attach the baseplate to the box with the two screws provided. 6) Snap the cover onto the baseplate top first then the bottom. 7) Place the knob on the switch and turn to the off position.

8)Restore the power to the furnace. 9) Set the temperature by turning the knob to the desired temperature.

Technical Assistance:

For technical assistance and support, call our customer service department at

901-745-9222 between 8 a.m. to 5 p.m. Central Standard Time, Monday through Friday.

Hunter Fan Company • 2500 Frisco Avenue • Memphis, TN 38114

Page 1
Image 1
Hunter Fan 40352, 40351 manual Line Voltage Thermostat Manual, Removal and Installation, Technical Assistance