®

3

 

 

Wire Labeling (Continued)

After labeling wires, disconnect them from the existing thermostat terminals.

Remove existing wallplate. To make sure wires do not fall back into wall opening, you may want to tape them to the wall.

If hole in wall is larger than necessary for wires, seal this hole with insulating material so that no hot or cold air can enter the back of the thermostat from the wall. This air could cause a false thermostat reading.

If the code letter on yourthen mark the wireand connect to thermostat
existing thermostat iswith label shownterminal shown

Position wallplate on wall and pull existing wires through large opening. Then level for ap- pearance. Mark holes for plastic anchors provided, if your existing holes do not line up with those on the Hunter wallplate.

Drill holes with 3/16” bit and gently tap anchors into the holes until flush with wall.

Reposition wallplate to wall, pulling wires through large opening. Insert mounting screws provided into wall anchor and tighten. See Figure 3.

NOTE: 5-wire Systems

If your thermostat has one wire marked R or RH (2, 3, or 4-wire system), then leave the jumper wire between the RH and RC terminals on the wallplate. Otherwise, if you have separate RH and RC wires (5-wire system), then remove the jumper wire between the RH and RC terminals.

RH, R, VR or 4 24 VoltRC, VC24 Volt CoolG or FFan

RH

x RH

RC

x

C

R

G

x G

Connect Wires and Mount Thermostat to Wallplate

■ Match and connect the labeled wires to the appropriate coded terminal screws on the

wallplate. (See Figure 4, 5.) Ignore any wires which may be present, but which were not con-

nected to the old thermostat.
■ Refer to the Wiring Diagrams below to be sure your system is wired correctly.

■ If your system is a single stage heat pump and uses an O or B wire, you must move the Sys-

tem Selector switch inside the thermostat to the Heat Pump position. If you have a normal

furnace or electric system, leave the switch in the Standard position. Refer to the System

Selector section for more information on this switch.

■ Be sure to tighten the terminal screws securely, otherwise a loose wire could cause opera-

Y, C or MAir Conditioning Compressor - or -

O

Reversing Valve operating in Cool mode. (Single Stage Heat Pumps ONLY.)

W or H Heating - or -

B

Reversing Valve operating in Heat mode. (Single Stage Heat Pumps ONLY.)

Y1

Heat Pump compressor (Single Stage Heat Pumps ONLY.)

Y/O

x

Y/O

W/B

x

W/B

Y1

x Y1

Table A
tional problems with your system or thermostat.

■ Push excess wire back into the hole to prevent interference when installing the thermostat to

the wallplate.

■ Make sure the System Switch is set to OFF, and the Fan Switch is set to AUTO.

■ Insert the bottom tab on the thermostat body into the slot at the bottom of the wallplate.

Press the top of the thermostat body to snap it into the wallplate. Refer to Figure 6. (NOTE:

Do not force the thermostat onto the wallplate, as the terminal pins may be
damaged. If it does not snap properly, the thermostat may not work.)

■ Insert the two AA size alkaline batteries, observing the polarity marked inside the battery

compartment.
■ Switch on the main power at the panel or furnace.

NOTE: Do not connect a “Common” wire (sometimes labeled “C”) to any terminal on this thermostat. Tape up the wire and do not use. This wire provides electricity to non- battery powered thermostats.

Mount Wallplate and Thermostat

Remove the wallplate from your thermostat by pressing the release tab on the bottom of the thermostat. See Figure 2.

Figure 2

RH

x

G Rc Rh Y/O W/B Y1

Figure 4

Figure 5

G

Rc

Rh

Y1

W/B

Y/O

Figure 3

Figure 6