Figure 4.

Hunter

Carrier

Coleman

Comfortmaker

Bryant, Payne

Rheem Ruud

Trane,

York

Lennox (1)

Lennox (2)

Weathertron

 

 

 

 

 

 

 

 

 

R

R

R

R

R

R

R

R

R

V-VR

Y

Y or Y1

Y

Y

Y

Y

Y

Y

Y

M

E

W2

W2

W1

W2

W2

W

W

W1

Y

 

E

E

Jumper to W2

E

E

X2

Jumper to W2

E

E

O

O

 

O

O

 

O

O

O

R

B

 

B

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

G

G

G

G

G

G

G

G

F

 

 

 

 

 

 

 

 

 

 

L

L or F

L

L or X

L

L

 

X

L

 

 

 

 

 

 

 

 

 

 

 

C

C

X

C, X, X1

C, X, X1

X

B

B

C

X

 

 

 

 

 

 

 

 

 

 

Conventional

Heat Pump

4 Wire Heat / Cool

5 Wire Heat / Cool

Single Stage Heat Pump

Thermostat Mounting Plate

Jumper

RH

RC

Y

G

W

W2

Y2

C

A

RH

Heat Power

 

Y

Cool Contactor

Fan Relay

G

Heat Contactor

W

 

Wall

Thermostat Mounting Plate

RH

RC

Y

G

W

W2

Y2

C

A

RH RC

Y

G

W

Heat Power

Cool Power

Cool Contactor

Fan Relay

Heat Contactor

Wall

Thermostat Mounting Plate

R

Y

G

L

O

B

Aux/E

Y2

C

Jumper

R

 

 

Y

 

G

O

Heat 24V Supply

Compressor Contact

Fan Relay

Cool Relay / Valve

Wall

Single Stage Heat Pump W/Aux Heat

3 Wire Cool Only

3 Wire Heat Only

Jumper

Thermostat Mounting Plate

Jumper

RH

RC

Y

G

W

W2

Y2

C

RC

Y

G

Cool Power

Cool Contactor

Fan Relay

Wall

Thermostat Mounting Plate

Jumper

RH

RC

Y

G

W

W2

Y2

C

RH

G

W

Heat Power

Fan Relay

Heat Contactor

Wall

Thermostat Mounting Plate

R

Y

G

L

O

B

Aux/E

Y2

C

R

Y

G

L

O

E

C

Heat 24V Supply

Compressor Contact

Fan Relay

System Monitor*

Cool Relay / Valve

Auxiliary Heat

Common*

Wall

A

A

*The common wire “C” and system monitor wire “L” may or may not be present.

Single Stage Heat Pump W/Heat Reversing

2 Wire Heat Only

3 Wire Hot Water with Damper Valve

Jumper

Thermostat Mounting Plate

Jumper

RH

RC

Y

G

W

W2

Y2

C

RH

W

Heat Power

Heat Contactor

Wall

Thermostat Mounting Plate

Jumper

RH

RC

Y

G

W

W2

Y2

C

RH

W

Heat Power

Heat Contactor

Wall

Thermostat Mounting Plate

R

Y

G

L

O

B

Aux/E

Y2

C

R

Y

G

L

B E

C

Heat 24V Supply

Compressor Contact

Fan Relay

System Monitor*

Heat Relay / Valve

Auxiliary Heat

Common*

Wall

A

A

A

Damper Valve

*The common wire “C” and system monitor wire “L” may or may not be present.

Multi-Stage Heat Pump

4 Wire with Common

Conventional Multi-Stage

Jumper

Thermostat Mounting Plate

Jumper

RH

RC

Y

G

W

W2

Y2

C

RH

Y

G

W

C

Heat Power

Cool Power

Cool Contactor

Fan Relay

Heat Contactor

Common

Wall

Thermostat Mounting Plate

Jumper

RH

RC

Y

G

W

W2

Y2

C

RC

Y

G

W

W2

Y2

Heat Power

Cool Contactor

Fan Relay

Heat Contactor

Second Stage Heat

Second Stage Cool

Wall

Thermostat Mounting Plate

R

Y

G

L

O

B

Aux/E

Y2

C

R

Y

G

L

O

E

Y2

C

Heat 24V Supply

Compressor Contact

Fan Relay

System Monitor*

Cool Relay / Valve

Auxiliary Heat

Second-Stage Cool

Common*

Wall

A

A

*The common wire “C” and system monitor wire “L” may or may not be present.

Page 2
Image 2
Hunter Fan 44272, 44277 Wire Heat / Cool, Wire Cool Only Wire Heat Only, Wire with Common Conventional Multi-Stage