® | 3 |
|
|
Wire Labeling (Continued)
■After labeling wires, disconnect them from the existing thermostat terminals.■Remove existing wallplate. To make sure wires do not fall back into wall opening, you may want to tape them to the wall.
■If hole in wall is larger than necessary for wires, seal this hole with insulating material so that no hot or cold air can enter the back of the thermostat from the wall. This air could cause a false thermostat reading.
■Position wallplate on wall and pull existing wires through large opening. Then level for ap- pearance. Mark holes for plastic anchors provided, if your existing holes do not line up with those on the Hunter wallplate.
■Drill holes with 3/16” bit and gently tap anchors into the holes until flush with wall.
■Reposition wallplate to wall, pulling wires through large opening. Insert mounting screws provided into wall anchor and tighten. See Figure 3.
NOTE:If the code letter on your existing thermostat is
RH, R, VR or4 24 Volt
RC, VC
24 Volt Cool
G or F
Fan
Y, C or M
Air Conditioning
Compressor
W or H
Heating
then mark the wire with label shown
RH
RC
G
Y
W
and connect to thermostat terminal shown
RH
x
RC
x
G
x
Y
x
W
x
If your thermostat has one wire marked R or RH (2, 3, or
Connect Wires and Mount Thermostat to Wallplate
■Match and connect the labeled wires to the appropriate coded terminal screws on the wallplate. (See Figure 4, 5.) Ignore any wires which may be present, but which were not con- nected to the old thermostat.
■Refer to the Wiring Diagrams below to be sure your system is wired correctly.■Be sure to tighten the terminal screws securely, otherwise a loose wire could cause opera- tional problems with your system or thermostat.
■Push excess wire back into the hole to prevent interference when installing the thermostat to the wallplate.
■Make sure the System Switch is set to OFF, and the Fan Switch is set to AUTO.■Insert the bottom tab on the thermostat body into the slot at the bottom of the wallplate. Press the top of the thermostat body to snap it into the wallplate. Refer to Figure 6. (NOTE:
Do not force the thermostat onto the wallplate, as the terminal pins may be damaged. If it does not snap properly, the thermostat may not work.)
■Insert the two AA size alkaline batteries, observing the polarity marked inside the battery compartment.
■Switch on the main power at the panel or furnace.NOTE: Do not connect a “Common” wire (sometimes labeled “C”) to any terminal on this thermostat. Tape up the wire and do not use. This wire provides electricity to non- battery powered thermostats.
Mount Wallplate and Thermostat
■Remove the wallplate from your thermostat by pressing the release tab on the bottom of the thermostat. See Figure 2.
Figure 2
W
| Y |
Rc | Rh |
|
G
Figure 3
Figure 4 | Figure 5 |