CALIBRATION INSTRUCTIONS

The spreader was factory calibrated, however, calibration should be checked occasionally to assure optimum performance.

1.Pull the on/off lever to the “OFF” position. Set the rate control plate to setting “B”.

Pointer

Pointer Screw

MODEL 70 PP

Rate Control Plate

Rate Control Knob

3.Loosen the rate control knob and slide the rate plate until the port is just opening. Loosen pointer screw and move pointer until it aligns with “B” on the rate plate. Retighten pointer screw.

VIEW IS

INSIDE OF

HOPPER

2.Flip on/off control lever to the “ON” position. Check the port opening. It should be just open. If adjustment is necessary, continue to step #3.

Port is just open

NOTES

7

Page 7
Image 7
Husqvarna 70 PP, 966043501 owner manual Calibration Instructions, View is Inside Hopper