P/N 374511B

Page 28

MAINT MENU

PROTOCOL

Hand Held Device

 

4- MAINT MENU

Press 4 on the Keypad to enter the Maintenance Menu Submenu. This screen has one function, four menus, and a second page.

The functions is: 2-CLEAR FORCE FLAG

Simply press 2 to activate clear function.

Press Numbers 1, 3, 4, 5 on the Keypad to enter the Submenu. Key in compressor or defrost circuit #. Press ENT.

The time limit on COMPRESSORS forced on/off is 20 minutes. After time limit expires, compressors return to normal operation.

The time limit for DEFROST CIRCUITS forced on is a function of the defrost length programmed for that circuit. For circuits forced out of defrost, operation is suspended for the current defrost only. Normal operation resumes at the next scheduled defrost.

Press ESC to return to MAIN MENU.

PROTOCOL MAIN MENU

1-STATUS MENU

2-CONFIG MENU

3-DEFROST MENU

4-MAINT MENU

5-ALARM MENU

MAINT MENU

1-FORCE A COMP ON

2-CLEAR FORCE FLAG

3-FORCE A COMP OFF

4-FORCE A DEFR ON

5-FORCE A DEFR OFF

PRESS ENT FOR MORE

 

FORCE A COMP ON

 

1

ENTER NUMBER

-

0

 

 

 

 

 

 

 

FORCE A COMP OFF

 

3

ENTER NUMBER

-

0

 

 

 

 

 

 

4

FORCE A DEFR ON

 

ENTER NUMBER

-

0

 

 

 

 

 

 

 

 

FORCE A DEFR OFF

 

5

ENTER NUMBER

-

0

 

 

 

 

HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 (Printed in U.S.A.)

970307