IDEAL INDUSTRIES C32 backPoints for Boiler User, Troubleshooting - Typical Non Product Faults

Models: C32 C28 C24 S28 S24

1 4
Download 4 pages 21.1 Kb
Page 4
Image 4
backPoints for Boiler User

backPoints for Boiler User

Note. In line with our current warranty policy we would ask that you check through the following guide to identify any problems external to the boiler prior to requesting a service engineers visit. Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not gained by the engineer.

Troubleshooting – Typical Non Product Faults

Problem

Solution

 

 

 

Is there power to the boiler i.e. is the left hand side green LED (A) alight and

 

flashing every 4 seconds. If not this is not a boiler fault – contact the installer

 

Check pressure gauge on boiler shows a minimum of 1 bar

Boiler is not working for

If not re-pressurise via the filling loop to 1 bar (if unsure contact your

installer), turn off the tap on the filling loop and press the reset button (D) to

central heating or hot water

reset the boiler. If unable to do so or if the pressure continues to drop after

 

 

filling then contact your installer

 

Is the lockout signal lamp (E) alight – Press boiler reset button (D) – If boiler

 

still does not fire contact the installer

Boiler goes through ignition

 

sequence but will not fire for

Check gas supply (try another gas appliance cooker/fire etc) If no gas

either central heating or hot

supply then this is not a boiler fault – Contact the gas supplier

water and then goes to

 

ignition lockout

 

 

 

Fan & pump run

Check that the air pressure switch test caps, on top of the boiler, are fitted

continuously but there is no

correctly.

attempt at ignition

 

 

 

Mini C Only

 

 

 

 

Check that integral programmer is set to an ‘on’ period and the function

 

switch is set to ‘auto’ – If it still does not operate contact your installer

Operating for hot water but

If fitted with an external programmer check that the central heating channel

is set at an ‘on’ period – If it still does not operate contact your installer.

will not operate for central

Check the room thermostat is set at the required temperature – Test the

heating

room thermostat by turning fully up – If this does not respond contact your

 

installer

 

Check the radiator temperature control (C) is set at the winter setting for

 

central heating.

The nature of all combination boilers is to heat up water directly from the incoming mains water supply directly through the boiler to supply domestic hot water at the stated flow rates, (as shown in the boiler installation instructions), to achieve a 35°C temperature rise. As the ambient temperature of the cold main varies during the summer and winter months it is likely in the colder winter months that the flow rate will need to be reduced at the outlet taps to achieve the same temperatures achieved in the warmer summer months. This is not a fault with the appliance but is relevant to the varying temperature of the incoming cold mains water supply.

Mini S Only

Operating for hot water but

If fitted with an external programmer check that the central heating channel

is set at an ‘on’ period – If it still does not operate contact your installer.

will not operate for central

Check the room thermostat is set at the required temperature – Test the

heating

room thermostat by turning fully up – If this does not respond contact your

 

installer

 

 

 

If fitted with an external programmer check that the domestic hot water

Operating for central heating

channel is set at an ‘on’ period – If it still does not operate contact your

installer.

but will not operate for hot

Check the cylinder thermostat is set at the required temperature – Test the

water

cylinder thermostat by turning fully up – If this does not respond contact

 

 

your installer

Ideal Consumer Helpline

Tel: 01482 498660

www.idealboilers.com

Caradon Ideal Limited pursues a policy of continuing improvement in the design and performance of its products. The right is therefore reserved to vary specification without notice.

Ideal Boilers, P.O. Box 103, National Ave, Kingston Upon Hull, HU5 4JN. Tel. 01482 492251 Fax. 01482 448858. Registration No. London 322 137.

Page 4
Image 4
IDEAL INDUSTRIES C32, S28, S24 backPoints for Boiler User, Troubleshooting - Typical Non Product Faults, Problem, Solution