Using External Strobes Cont.
Using Ikelite
The Conversion Circuitry is automatically disabled when used with a
Using Non Ikelite Strobes with this Housing.
The Conversion Circuitry is automatically disabled when used with a Non Ikelite Strobe. Non Ikelite strobes can be used in their manual mode utilizing any power settings provided on the strobe.
Strobe Arms
This housing offers two types of arm mounting systems. The top of the rubber handles utilize Ikelite’s
The bottom of the rubber handles have a wing nut that accepts the Ikelite Tray Mount. The Tray Mount comes with the Ikelite
Lubricants
1. Ikelite provides silicone lubricant with the housing. We recommend that you use only Ikelite lubricant as some other brands may cause the o’ring to swell and not seal properly.
2. Use only enough lubricant to lightly cover control shafts and o’rings. Wipe off any excess lubricant with a clean cloth. Lubricant is not a sealant, it is used to reduce friction. Excessive lubricant can collect sand and dirt which may interfere with proper sealing.
CAUTION
Never use spray lubricants as the propellant ingredient can 17 cause the plastic housing to crack.
Port Information
While we have included a list of our ports and a short list of Lenses and port recommendations we suggest visiting our web site for the latest information on lenses and port recommendations.
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| •With the lens on the camera extended to | |
|
|
|
|
|
|
| full length, measure from front of camera | |
|
|
|
|
|
|
| to face of lens. |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| •Select the appropriate port based on the | |
|
|
|
|
|
|
| lens type and length. |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| •Maximum lens diameter accommodated is | |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
|
| Measure | 8.4cm (3.3") |
| ||||
|
|
|
|
|
|
| •Maximum lens diameter when using |
|
|
|
|
|
|
|
|
| |
Choosing a Port | zoom or focus clamp 7.1cm (2.8") |
| ||||||
DOME PORT 6” |
|
| ||||||
#5503........Wide angle 28mm to 17mm |
| |||||||
or lens up to 7.6cm (3") in length |
| |||||||
#5503.20 ..Nikon 18 & 20mmD lenses |
| |||||||
#5503.50 ..Lens |
| |||||||
#5503.55....Lens |
| |||||||
#5503.80 ..Lens |
| |||||||
#5503.81....Nikkor |
| |||||||
#5503.85 ..Lens |
| |||||||
SUPERWIDE DOME PORT 6” |
| |||||||
#5503.15 ........Lens up to 6.3cm (2.5") |
| |||||||
DOME PORT 8” |
|
| ||||||
#5510.80 ..8” Dome Port (see lens & port recommendations) |
| |||||||
Some zoom lenses may require the addition of a +diopter | 19 | |||||||
(Available from camera store). |
Pre-Dive Your System
It is recommended that you take the complete system into a swimming pool before use in open water. This will give you a chance to become familiar with the handling and operation of your housing and strobe(s).
Optional Accessories
Lead Weight #0906.58
The buoyancy of the system will depend on the size and number of strobes used as well as the weight of the camera. Ideally the system should be slightly negative in the environment in which it will be used. If you need to add weight to the system, an optional lead weight is available. To add the lead weight remove the (2) screws from the bottom of the aluminum tray. Place the lead weight into the pocket of the aluminum tray and reattach.
Ikelite Lube #0184.1
Port O’ring #0105
Housing Back O’ring #0132.61
While both the Port and Back o’rings should last quite some time it is best to carry a spare in case one becomes damaged or lost.
Housing Back O’ring & Port O’ring Kit #5512.69
18
Lens & Port Recommendations
For thelatest informationon Lens & Port recommendations visit our web siteatwww.ikelite.com or contactIkelite.
Not Recommended |
| |
Not Recommended | 5510.81 | |
5503.50 | ||
5503.50 | 5510.81 | |
5503.80 | 5510.81 | |
5503.50 | 5510.81 | |
5510.81 | ||
5503.80 | 5510.81 | |
5503 | 5510.81 | |
5503.50 | 5510.81 | |
5503.50 | 5510.81 | |
5503.80 | 5510.81 |
(*) Zoom lenses that do not focus to 12” require a +4 diopter
(9)
Storing the Housing
When the housing is going to be stored for a prolonged period the exterior of the housing should be soaked in a mild soap solution, rinsed and dried thoroughly. Then remove the back and port from the housing. Remove the back and port o’rings, lightly lubricate them and place them in a plastic
20