Switch Settings for Switch S3

 

 

 

Reserved

 

 

 

 

 

S3-1: ON

Reserved

 

 

 

 

S3-1: OFF

Reserved

 

 

default

 

Remote Management

 

 

 

 

S3-2: ON

Remote Management Enabled (only at the REMOTE end)

 

 

 

S3-2: OFF

Remote Management Disabled (only at the LOCAL end)

 

default

 

Loopback Selection iVIEW2

 

 

 

 

S3-3: ON

S3-4: ON

None

iVIEW2

default

S 3

S3-3: OFF

S3-4: ON

Fiber Analog Loopback

iVIEW2

 

S3-3: ON

S3-4: OFF

Internal Fiber Loopback

iVIEW2

 

H

S3-3: OFF

S3-4: OFF

Copper Remote Loopback

iVIEW2

 

Monitor/Boost Mode

 

 

 

C

 

 

 

S3-5: ON

S3-6: ON

Normal Operation (No Boost)

 

default

I T

 

S3-5: OFF

S3-6 ON

20 dB

 

 

W

S3-5: ON

S3-6 OFF

26 dB

 

 

S3-5: OFF

S3-6 OFF

32 dB

 

 

S

 

 

Fault Loopback

 

 

 

 

 

 

 

 

 

 

S3-7: ON

Send AIS is sent back toward the fault on the RJ-45 port

iVIEW2

 

 

S3-7: OFF

AIS is only sent toward the fiber on detecting a fault on the

iVIEW2

default

 

 

RJ-45 port

 

 

 

 

Fiber Type

 

 

 

 

 

S3-8: Factory Configured

DO NOT CHANGE

 

 

 

S3-9: Factory Configured

DO NOT CHANGE

 

 

 

S3-10: Factory Configured

DO NOT CHANGE

 

 